Subject to modifications hereinafter set forth, the following codes, regulations and records are hereby expressly incorporated into the Bartlett building code by this reference, and are adopted as the Bartlett building code, pursuant to section 1-3-2 of the Illinois municipal code 1 , which authorizes municipalities to incorporate by reference the provisions of nationally recognized technical codes and records:
A. The international building code, 2018 edition (the "IBC") (with amendments);
B. The Illinois energy conservation code, latest edition (the state energy conservation code "IECC") including all published errata and excluding published supplements that encompass ASHRAE 90.1 (with amendments);
C. The international residential code, 2018 edition (the "IRC") including appendices F (with amendments);
D. The international mechanical code, 2018 edition (the "IMC") (with amendments). See chapter 11 of this title;
E. The Illinois plumbing code, latest edition, and as hereafter amended from time to time (the "state plumbing code") (with amendments). See chapter 10 of this title;
F. The national electrical code, 2017 edition (the "NEC") (with amendments). See chapter 9 of this title;
G. The 2018 Illinois accessibility code, latest edition, and as hereafter amended from time to time;
H. The international property maintenance code, 2018 edition (the "IPMC") (with amendments). See chapter 13 of this title;
I. The international fire code, 2018 edition (the "IFC") (with amendments, including appendices B, C, D);
J. The international fuel gas code, 2018 edition (the "IFGC");
K. The international existing building code, 2018 edition (the “IEBC”).
L. The international swimming pool and spa code, 2018 edition (the “ISPSC”).
IRC Table R301.2(1) Manual J Design Criteria
Elevation: 758 (West Chicago)
Latitude: 41
Winter Heating: 0
Summer Cooling: 88
Altitude Correction Factor: 0
Indoor Design Temperature: 72 degrees F maximum
Design Temperature Cooling: 75 degree F minimum
Heating Temperature Difference: 73 degrees F
Cooling Temperature Difference: 16 degrees F
Wind Velocity Heating: 8.4 mph
Wind Velocity Cooling: 5.7 mph
Coincident Wet Bulb: 74
Daily Range: Medium (16-25 degrees)
Winter Humidity: 30%
Summer Humidity 50%
* Manual J, Residential Load Calculation, ACCA, Eighth Edition, Version 2, Aurora
Except for the deletions, modifications, additions, clarifications, elections and amendments that follow in this title, all provisions (except appendices unless indicated) of the foregoing codes incorporated herein by reference are expressly made part of this code just as if they were fully set forth herein. The following deletions, changes, additions, clarifications, elections and amendments in section 9-1-3 of this chapter, and the deletions, modifications, changes, additions, clarifications, elections and amendments and provisions set forth in chapters 2 through and including 23 of this title (collectively the "local amendments"), shall supersede the requirements in the codes adopted in this section. (Ord. 2014-46, 6-3-2014; amd. Ord. 2020-56, 6-16-2020; Ord. 2022-07, 1-18-2022)