9-1-3: TABLE OF DELETIONS, MODIFICATIONS AND CLARIFICATIONS FOR BARTLETT, ILLINOIS:
IBC
Section 101.1 Insert the village of Bartlett.
Section 113 Delete the section: Board Of Appeal, and replace with section 9-23-3 of the Bartlett municipal code.
Amend chapter 9- For changes to the requirements for fire protection systems see Chapter 9 of the international fire code.
Delete chapter 11 accessibility and replace with latest edition of Illinois accessibility code.
Section 1612.3 Insert the village of Bartlett and map #170059-17031C-17043C-17089C.
Amend section 1807.1.4 Permanent Wood Foundation Systems; Delete the section and insert: "Wood foundations are prohibited".
Delete section 1809.8 Concrete Footings.
Amend section 1904.3 Insert Chlorides are not allowed.
Amend section 2308 Light Weight Wood Framing, see section 9-8-11 of the Bartlett municipal code.
Amend chapter 30 section 3001.1 Scope: Design, Construction, Alteration the current edition of the Illinois elevator safety rules and section 3004 Conveying Systems.
Delete the following from chapter 35 all appendixes.
All references throughout this code to the international plumbing code shall be deleted and changed to the Illinois state plumbing code. All references throughout this code to the international energy conservation code shall be deleted and changed to the Illinois state energy conservation code.
All references to the Director, Building Director, Village Building Director, Village of Bartlett Building Director or Bartlett Building Director in this title shall be deleted and amended to replace any such term with the following term: "Building and Code Enforcement Division Manager".
All references to the "Building Department", "Bartlett Building Department" or "Village of Bartlett Building Department" shall be deleted and amended to replace any such term with "Building Division" or "Building and Code Enforcement Division" of the Planning and Development Services Department".
IRC
IRC Table R301.2(1)
Ground snow load
30
Wind speed
3 second gusts at 107 mph.
Seismic design category
B
Weathering
Severe
Frost line depth
42 inches
Termite
Moderate to heavy
Winter design temperature
-4 degrees
Ice shield underlayment
Yes
Flood hazard
C or X zone; see local flood zone map (170059)
Air freezing index
2000
Mean annual temperature
50 degrees
 
Section R101.1: IRC section Insert the village of Bartlett.
Delete section R101.2 Exceptions 1 and 2 and replace with:
   Exceptions:
   1. Live/work units complying with the requirements of section 419.5 of the international building code shall be permitted to be constructed in accordance with this code.
   2. Owner-occupied lodging house with five or fewer guestrooms shall be permitted to be constructed in accordance with this code.
Section R112 Delete the section: Board Of Appeal, and replace with section 9-23-3 of the Bartlett municipal code.
Section R302.3 Amend 1 hour fire resistance rating to 2 hour.
Amend table R302.6 A minimum or not less than 5/8-inch type X gypsum board.
Delete section R313.1 and R313.2 Automatic Fire Sprinkler Systems. Keep R313.1.1 and R313.2.1.
Delete sections R402.1, R404.2, R405.2 and R406.3 and all subsections and insert: "Wood foundations are prohibited".
Amend section R402.2 - Chlorides Not Allowed.
Delete section R602.3.2 Exception, section R602.3.3 Not less than 16" inch on center.
Delete chapters 11-43 and all referenced standards within.
Insert under part IV - Energy Conservation: Illinois state energy conservation code.
Insert under part V - Mechanical: International mechanical code 2018 w/ Bartlett amendments.
Insert under part VI - Fuel Gas: International fuel gas code 2018.
Insert under part VII- Plumbing: Illinois state plumbing code w/ Bartlett amendments.
Insert under part VIII - Electrical: National electric code 2017 w/ Bartlett amendments.
IPMC
Revise section 102.4 add “or” before insanitary.
Insert section 102.7.1.2. Conflicts. Provisions: More restrictive requirements shall apply.
Delete section 202 Definition “Public Way” verbiage and add has a clear width and height of not less than 10 feet.
Delete section 107.2 # 5. Notice to property owner regarding appeals.
Add to section 108.2 and 108.4 all placards will apply (not just condemnation).
Delete section 109.6.
Delete section 111 Means Of Appeal and add section 9-23-3 of the Bartlett municipal code.
Add to section 305.4 anchored or firmly fastened.
Add to section 404.4.1 for each occupant thereof, not to exceed three (3) occupants per bedroom regardless of square foot area. (Ord. 2014-46, 6-3-2014; amd. Ord. 2020-56, 6-16-2020; Ord. 2022-07, 1-18-2022)