Skip to code content (skip section selection)
Compare to:
Toledo Overview
Toledo Municipal Code
TOLEDO MUNICIPAL CODE
CERTIFICATION
ADOPTING ORDINANCE
EDITOR'S NOTE
COMPARATIVE SECTION TABLE
CHARTER OF THE CITY OF TOLEDO, OHIO
PART ONE - ADMINISTRATIVE CODE
PART THREE - TRAFFIC CODE
PART FIVE - GENERAL OFFENSES CODE
PART SEVEN - BUSINESS REGULATION CODE
PART NINE - STREETS, UTILITIES AND PUBLIC SERVICES CODE
TITLE ONE - Streets, Sidewalks and Public Grounds
TITLE THREE - Utilities
CHAPTER 925 Sewer Definitions and Construction Standards
CHAPTER 927 Sewer Connections and Use
CHAPTER 929 Sewer Service Charges
CHAPTER 930 Sewer Discharge Control
CHAPTER 931 Special Sewer Provisions and Payments
CHAPTER 932 Roadside Drainage Systems
CHAPTER 933 Water Rates
CHAPTER 935 Nonresident Water Service
CHAPTER 937 Water Meters
CHAPTER 939 Water Regulations
CHAPTER 941 Storm Water Discharge Control
CHAPTER 943 Storm Water Management Program
CHAPTER 945 Management and Control of the Public Right of Way
CHAPTER 947 Provision of Electric Energy
CHAPTER 949 Toledo Public Power
APPENDIX A
APPENDIX B
APPENDIX C
APPLICABILITY
DEFINITIONS
CHAPTER 100 GENERAL ADMINISTRATION
CHAPTER 101 APPLICATION FOR UTILITY SERVICES
CHAPTER 102 CUSTOMER OBLIGATIONS
CHAPTER 103 SERVICE DISCONNECTIONS
CHAPTER 104 BILLING
CHAPTER 105 APPEAL PROCESS
CHAPTER 106 COLLECTIONS
CHAPTER 107 DEPARTMENT ACTIONS
CHAPTER 108 TYPES OF ACCOUNTS
CHAPTER 200 WATER SERVICES (TAPS AND CUSTOMER BRANCHES)
CHAPTER 201 METERS
CHAPTER 202 FIRE PROTECTION SERVICES
CHAPTER 203 PUBLIC HYDRANTS
CHAPTER 204 CROSS CONNECTIONS
CHAPTER 205 WATER SERVICE MAIN EXTENSIONS
CHAPTER 206 REGULATIONS FOR CONTRACTORS
CHAPTER 207 RIGHTS OF ENTRY
CHAPTER 300 WASTEWATER HAULING REGULATIONS
CHAPTER 400 STORM AND SANITARY SEWERS
CHAPTER 401 PLATS
CHAPTER 402 SIDEWALK POLICY OF THE CITY OF TOLEDO
CHAPTER 403 STORM WATER ERU APPEAL
CHAPTER 404 RIGHT-OF-WAY OCCUPANCY PERMIT APPEALS
CHAPTER 405 RIGHT-OF-ENTRY ON PRIVATE PROPERTY
CHAPTER 500 (Reserved)
CHAPTER 600 SEWER DISCHARGE CONTROL APPEAL
CHAPTER 601 STORM WATER DISCHARGE APPEAL
ATTACHMENT 1 FEE SHEET OF THE DIRECTOR OF PUBLIC UTILITIES
ATTACHMENT 2 JUDGMENT ENTRY (BY CONSENT) McDOWELL v. TOLEDO
APPENDIX D
TITLE FIVE - Other Public Services.
PART ELEVEN - PLANNING AND ZONING CODE
PART TWELVE - DEVELOPMENT CODE
PART THIRTEEN - BUILDING CODE
PART FIFTEEN - FIRE PREVENTION CODE
PART SEVENTEEN - HEALTH CODE
PART NINETEEN - TAXATION CODE
PART TWENTY-ONE - PERSONNEL RELATIONS AND MUNICIPAL EMPLOYMENT
Loading...
200.08 Workmanship On Customer's Branch
   A.    Installation work on Customer's Branches shall be in accordance with the best journeyman practice and these Rules and Regulations and ordinances of the City.
   B.   The Customer's Branch shall be without joints to a point one foot (1') outside the property line using copper tubing. The pipe shall have a constant internal diameter from the tap through and including the locking ball valve. The pipe shall have a full waterway throughout, equal to the inside diameter of the pipe. Pipe ends shall be reamed to remove any obstruction to the flow of water. Where joints are needed, they shall be of the flare type only. Any exception requires the written approval from the Division of Water Distribution.
   C.   Where two incompatible metals are used in a service, a dielectric union between said metals shall be required.
200.09 Depth Of Pipe
   All service pipe outside buildings, from the water Main to the meter, shall have a minimum cover of four feet (4') for pipe smaller than four inches (4") and a minimum cover of five feet (5') for pipe four inches (4") and larger. The cover shall be of earth and/or granular material. Service Lines in crawl spaces and unheated buildings shall be insulated from the point the Service Line starts an incline from this cover to the floor material where the meter setting is installed. The use of heat tape or similar products shall not be allowed.
200.10 Customer's Branch Location And Construction
   A.    The Customer's Branch shall be installed in a direct line from the house to the street, and at right angles to the street. The Service Line shall enter the structure at a point on the foundation wall closest to the tap. If the Branch enters the building from the side, it shall be installed at right angles to the street and no further than three feet (3') from the building. If local conditions do not permit, a deviation may be permitted; however, the location must be approved in writing by the Department. The Customer's Branch shall not be laid closer than ten feet (10') from a leach field/Septic system, sanitary sewer, storm sewer, nor closer than four feet (4') to any drain, gas line or other underground facility for the entire length of the Branch line.
   B.   At least one foot (1') of the Customer's Branch pipe shall extend above ground beyond the point where the curb box is set which is one foot (1') toward the water main from the property line.
   C.   The Customer's Branch must be in place before the Division of Water Distribution will install the tap branch. The Owner, Customer or representative shall notify the Division of Water Distribution that the Customer's Branch is in place. The priority of the tap installation will be as of the date and time of approval of the Customer's Branch.
   D.   The Customer's Branch shall be so valved and/or controlled that after it is connected to the tap branch, the curb stop valve could be left open. The Department will not be held responsible for any damages which occur due to improperly installed Customer Branches.
   E.   Water mains will be tapped before building construction (pre-tapped) when, in the opinion of the Division of Water Distribution, savings in time and construction expenses or hazards will be the result. Procedures, rules and authority shall be established by the Division of Water Distribution.
   F.   On corner lots, the Customer shall contact the Division of Water Distribution to determine in which direction to install the Customer's Branch. It is the intent of the Division to require the tap to be made from the direction of the shortest distance from the water main.
   G.   Taps that are not located in accordance with this section will result in any additional costs necessitated by the improper placement being assessed to the builder.
200.11 Plans - Large Services (Over 2")
   Six (6) detailed sets of plans and specifications on all large underground domestic services shall be furnished to and approved by the Division of Engineering Services before service will be granted. Design and construction shall be in conformance with the latest version of the Division of Engineering Services "Infrastructure Design and Construction Requirements" or a successor publication approved by the Department. The plans shall include the profile of the service within the public right-of-way, if requested by the Division of Engineering Services. Payment of the plans review and inspection fee shall be required prior to plan approval.
200.12 Control Valves - Large Services
   A.   The primary control valve for the service at the outlet on the public water Main shall be in a valve box as required by the Division of Water Distribution and constructed by the property Owner.
   B.   All secondary valves shall be at the option of the property Owner.
   C.   Secondary valves shall have adjustable valve boxes.
   D.   All domestic services off fire mains and domestic service extensions shall have a primary valve at the beginning of the service or the extension of the service.
   E.   Where a domestic tap is made off a fire line, the tap shall be made on the outside of the structure and a separate curb box provided for the domestic service.
200.13 Customer's Branch Leaks
   A.   When a leak on a Customer's Branch between the curb stop and the meter comes to the attention of the Division of Water Distribution, the Owner and/or Customer may be notified by a notice left at the Premises. This notice will contain a directive to repair the leak with reasonable dispatch. If the Owner and/or Customer have not taken positive steps to repair the leak within five (5) days, the water service to the Premises may be turned off at the curb stop.
   B.   Water service to the Premises shall not be restored until the ordered repairs have been completed. If deemed necessary by the Division of Water Distribution, on the basis of age and condition of the pipe, the entire Customer's Branch shall be replaced with type "K" soft copper sized as herein specified. If the leaking service is causing damage or a hazardous condition it may be turned off immediately, without prior notice.
Loading...