(a) Only metal support, galvanized construction, or another material deemed by the Building Commissioner to be equal thereto with a minimum of schedule 40 pipe, shall be allowed in the construction of the dish antenna support structure.
(b) Only a concrete base or caisson shall be used in line with grade.
(c) The structure shall be designed to withstand a wind force of up to ninety miles per hour.
(d) Any driving motor shall be encased in protective guards.
(e) All electrical wiring shall be installed in accordance with the National Electrical Code as adopted by the City in Chapter 1406.
(f) The dish antenna shall be bonded to an eight foot grounding rod.
(g) If guy lines are to be used, they shall be confined within the setbacks established in this Chapter.
(h) All plans shall meet good engineering and architectural standards.
(Ord. 2000-30. Passed 7-24-00.)