9.28.060: USE DISTRICTS AND PERMITTED NOISE LEVELS:
   A.   Maximum Permissible Sound Levels: It is a violation of this chapter for any person to operate or permit to be operated any stationary source of sound in such a manner as to create a ninetieth percentile sound pressure level (L90) of any measurement period (which shall not be less than 10 minutes unless otherwise provided in this chapter) which exceeds the limits set forth for the following receiving land use districts, when measured at the boundary or at any point within the property affected by the noise:
 
Weekdays And Saturdays
Use District
9:00 P.M. - 7:00 A.M.
7:00 A.M. - 9:00 P.M.
Residential
50 dBA
55 dBA
Commercial-agricultural
55 dBA
60 dBA
Industrial
75 dBA
80 dBA
 
Sundays And Holidays
 
9:00 P.M. - 9:00 A.M.
9:00 A.M. - 9:00 P.M.
Residential
50 dBA
55 dBA
Commercial-agricultural
55 dBA
60 dBA
9:00 P.M. - 7:00 A.M.
7:00 A.M. - 9:00 P.M.
Industrial
75 dBA
80 dBA
 
When a noise source can be identified and its noise measured in more than one land use category, the limits of the most restrictive use shall apply at the boundaries between different land use categories.
   B.   Correction For Duration Of Sound:
      1.   It is a violation of this chapter for any person to operate, or permit to be operated, any stationary source of sound within any land use district which creates a tenth percentile sound pressure level (L10) of fifteen (15) dBA greater than the levels set forth for the receiving land use districts in subsection A of this section for any measurement period. Such period shall not be less than ten (10) minutes.
      2.   Notwithstanding subsection B1 of this section, it is a violation of this chapter for any person to operate, or permit to be operated, any stationary source of sound within any land use district which creates a tenth percentile sound pressure level (L10) greater than fifteen (15) dBA above the ambient and sound pressure level (L90) of any measurement period. Such period shall not be less than ten (10) minutes.
   C.   Correction For Character Of Sound:
      1.   For any stationary source of sound which emits a pure tone, cyclically varying sound or repetitive impulsive sound, the limits set forth in subsection A of this section shall be reduced by five (5) dBA.
      2.   Notwithstanding compliance with subsection C1 of this section, it is a violation of this chapter for any person to operate or permit to be operated any stationary source of sound which emits a pure tone, cyclically varying or repetitive impulsive sound which creates a noise disturbance. (Prior code § 18-33-4)