FLAMMABLE LIQUIDS
§ 98.001 PROHIBITION.
§ 98.002 ENFORCEMENT.
§ 98.003 CLASSIFICATION.
§ 98.004 SMALL STORAGE LIMITED.
§ 98.005 GENERALLY; ABOVE GROUND STORAGE TANKS.
§ 98.006 GASOLINE CONTAINERS MUST BE RED.
§ 98.007 EMPTY DRUMS.
§ 98.008 USE WITHIN BUILDING RESTRICTED.
§ 98.009 POURING INTO SEWERS PROHIBITED.
§ 98.010 STORAGE IN PUBLIC BUILDINGS RESTRICTED.
§ 98.011 USE IN STARTING FIRES.
§ 98.012 FIRE TO BE KEPT AWAY FROM FLAMMABLE LIQUIDS.
§ 98.013 LOCATION OF TANKS; RESTRICTED CLASSES OF PROPERTY.
§ 98.014 LOCATION OF TANKS; PROPERTY LINES AND BUILDINGS.
§ 98.015 DISTANCE BETWEEN TANKS.
§ 98.016 CONSTRUCTION OF TANKS; SPECIFICATIONS.
§ 98.017 NORMAL VENTS IN TANKS.
§ 98.018 SPECIAL SAFETY OR EMERGENCY VENTS IN TANKS.
§ 98.019 SETTING OF TANKS.
§ 98.020 GROUNDING OF TANKS.
§ 98.021 PIPING MATERIAL.
§ 98.022 PIPING RUNS.
§ 98.023 PIPING ABOVE GROUND.
§ 98.024 PIPING UNDERGROUND.
§ 98.025 JOINTS IN PIPES.
§ 98.026 TESTS OF PIPING.
§ 98.027 NORMAL VALVES IN PIPES.
§ 98.028 EMERGENCY INTERNAL CHECK VALVES.
§ 98.029 DIKES REQUIRED.
§ 98.030 CAPACITY OF DIKES.
§ 98.031 MATERIALS AND CONSTRUCTION OF DIKES.
§ 98.032 NO OPENINGS IN DIKES PERMITTED.
§ 98.033 BUILDINGS; GENERAL REQUIREMENTS.
§ 98.034 PUMPHOUSE.
§ 98.035 CONSTRUCTION OF WAREHOUSE.
§ 98.036 CONSTRUCTION OF GARAGE.
§ 98.037 LOCATION OF LOADING DOCK.
§ 98.038 ELECTRICAL EQUIPMENT.
§ 98.039 PUMPS AND PIPE LINES.
§ 98.040 GROUNDING.
§ 98.041 NO UNLOADING BY GRAVITY.
§ 98.042 NO UNLOADING TO PORTABLE CONTAINERS.
§ 98.043 DOME COVERS.
§ 98.044 OTHER RESTRICTIONS.
§ 98.045 GROUNDING.
§ 98.046 FENCING.
§ 98.047 CARE AND ATTENDANCE.
§ 98.048 FIRE PROTECTION.
§ 98.049 NO STORAGE WITHIN BUILDING.
§ 98.050 TANKS, TRUCKS AND WAGONS.
§ 98.051 PERMITS.
§ 98.052 APPROVAL.
§ 98.053 FEES.
§ 98.054 SERVICE STATIONS.
§ 98.055 DEFINITION.
LIQUIFIED PETROLEUM GASES
CHAPTER 99: EXPLOSIVES AND FIREWORKS
CHAPTER 100: CEMETERIES
CHAPTER 101: PUBLIC GATHERING
TITLE XI: BUSINESS REGULATIONS
TITLE XIII: GENERAL OFFENSES
TITLE XV: LAND USAGE
TABLE OF SPECIAL ORDINANCES
PARALLEL REFERENCES
Loading...
§ 98.016 CONSTRUCTION OF TANKS; SPECIFICATIONS.
   (A)   Tanks shall be covered with asphaltum or other non-rusting coating or paint.
   (B)   All pipe connections shall be made through flanges or reinforcements securely riveted, welded or bolted to the tank and shall be made tight.
   (C)   All openings shall be made liquid and vapor tight, except breather vents. Gaskets used shall be such as are not affected by heat or the contents of the tank.
   (D)   Covers for manholes, handholes and gauge holes shall be made tight fitting and normally kept in place.
(1980 Code, § 27.016) Penalty, see § 98.999
§ 98.017 NORMAL VENTS IN TANKS.
   (A)   Each tank over 100-gallon capacity shall have vent openings, except safety valves, provided with approved non-corrodible flame arresters so attached as to completely cover the openings.
   (B)   Vent openings shall be in no case less than one-fourth inches in diameter, and where a power pump is used in filling tanks and a tight connection is made to fill pipe, vent shall not be smaller than fill pipe.
(1980 Code, § 27.017) Penalty, see § 98.999
§ 98.018 SPECIAL SAFETY OR EMERGENCY VENTS IN TANKS.
   (A)   Additional vent openings or safety valves adequate to relieve any excessive pressure due to external heat shall be provided, of a type which shall be self-closing when pressure is relieved.
   (B)   The total area of vents shall not be less than 24 square inches for tanks of 21,000 gallons capacity or less; and 21,000 gallons capacity.
(1980 Code, § 27.018) Penalty, see § 98.999
§ 98.019 SETTING OF TANKS.
   (A)   Tanks more than one foot above the ground shall have a firm foundation and supports of noncombustible materials, bases of which shall rest below the frost line.
   (B)   Unprotected steel as a support for tanks shall not be permitted. No combustible materials shall be permitted under or within ten feet of any storage tanks except stairways to and walks on top which shall be incombustible.
(1980 Code, § 27.019) Penalty, see § 98.999
§ 98.020 GROUNDING OF TANKS.
   All tanks shall be grounded electrically and effectively to permanent moisture.
(1980 Code, § 27.020) Penalty, see § 98.999
§ 98.021 PIPING MATERIAL.
   (A)   All piping shall be standard full weight wrought iron or steel for working pressures less than 100 pounds; for working pressure in excess of 100 pounds, extra heavy pipe and fittings shall be used.
   (B)   No pipe less than one-half inch internal diameter will be permitted.
(1980 Code, § 27.021) Penalty, see § 98.999
§ 98.022 PIPING RUNS.
   Piping shall be run as directly as possible and proper allowance be made for expansion and contraction.
(1980 Code, § 27.022) Penalty, see § 98.999
§ 98.023 PIPING ABOVE GROUND.
   Piping when above ground shall be protected against mechanical injury.
(1980 Code, § 27.023) Penalty, see § 98.999
Loading...