Loading...
All elevations noted in the construction documents shall be referred to and clearly identified as the North American vertical datum of 1988 (NAVD) as established and maintained by National Geodetic Survey of the National Ocean Service, National Oceanic and Atmospheric Administration or successor agency, which is hereby established as the city datum. Neither the United States coast and geodetic survey mean sea level datum of 1929, national geodetic vertical datum (NGVD) nor any of the five borough data as established by the former Board of Estimate and Apportionment shall be referred to in construction documents except as may be required for the purpose of demonstrating conversion to the NAVD. Conversions to NAVD shall be performed by registered design professionals or surveyors. Conversion to and from borough data, NGVD and NAVD shall be performed using tables 104.7.6.1 through 104.7.6.5.
Bronx Elevations | To obtain equivalency: | NGVD Elevations | To obtain equivalency: | NAVD Elevations |
8.422 to 8.495 | —> add 2.608 —> | 11.030 to 11.083 | —> subtract between 1.030 and 1.083 —> | 10.000 |
10.000 | —> add 2.608 —> | 12.608 | —> subtract between 1.030 and 1.083 —> | 11.525 to 11.578 |
7.392 | —> add 2.608 —> | 10.000 | —> subtract between 1.030 and 1.083 —> | 8.917 to 8.970 |
a. Conversions to and from NAVD as indicated in this table represent the likely range. The precise conversion depends on the latitude and longitude of the location in question, as determined by a surveyor.
Brooklyn Elevations | To obtain equivalency: | NGVD Elevations | To obtain equivalency: | NAVD Elevations |
8.546 to 8.572 | —> add 2.547 —> | 11.093 to 11.119 | —> subtract between 1.093 and 1.119 —> | 10.000 |
10.000 | —> add 2.547 —> | 12.547 | —> subtract between 1.093 and 1.119 —> | 11.428 to 11.454 |
7.453 | —> add 2.547 —> | 10.000 | —> subtract between 1.093 and 1.119 —> | 8.881 to 8.907 |
a. Conversions to and from NAVD as indicated in this table represent the likely range. The precise conversion depends on the latitude and longitude of the location in question, as determined by a surveyor.
Manhattan Elevations | To obtain equivalency: | NGVD Elevations | To obtain equivalency: | NAVD Elevations |
8.288 to 8.357 | —> add 2.752 —> | 11.040 to 11.109 | —> subtract between 1.040 and 1.109 —> | 10.000 |
10.000 | —> add 2.752 —> | 12.752 | —> subtract between 1.040 and 1.109 —> | 11.643 to 11.712 |
7.248 | —> add 2.752 —> | 10.000 | —> subtract between 1.040 and 1.109 —> | 8.891 to 8.960
|
a. Conversions to and from NAVD as indicated in this table represent the likely range. The precise conversion depends on the latitude and longitude of the location in question, as determined by a surveyor.
Queens Elevations | To obtain equivalency: | NGVD Elevations | To obtain equivalency: | NAVD Elevations |
8.361 to 8.381 | —> add 2.725 —> | 11.086 to 11.106 | —> subtract between 1.086 and 1.106 —> | 10.000 |
10.000 | —> add 2.725 —> | 12.725 | —> subtract between 1.086 and 1.106 —> | 11.619 to 11.639 |
7.275 | —> add 2.725 —> | 10.000 | —> subtract between 1.086 and 1.106 —> | 8.914 to 8.894
|
a. Conversions to and from NAVD as indicated in this table represent the likely range. The precise conversion depends on the latitude and longitude of the location in question, as determined by a surveyor.
Staten Island Elevations | To obtain equivalency: | NGVD Elevations | To obtain equivalency: | NAVD Elevations |
7.835 to 7.917 | —> add 3.192 —> | 11.027 to 11.109 | —> subtract between 1.027 and 1.109 —> | 10.000 |
10.000 | —> add 3.192 —> | 13.192 | —> subtract between 1.027 and 1.109 —> | 12.083 to 12.165 |
6.808 | —> add 3.192 —> | 10.000 | —> subtract between 1.027 and 1.109 —> | 8.891 to 8.973 |
a. Conversions to and from NAVD as indicated in this table represent the likely range. The precise conversion depends on the latitude and longitude of the location in question, as determined by a surveyor.
(Am. L.L. 2021/126, 11/7/2021, eff. 11/7/2022; Am. L.L. 2023/077, 6/11/2023, eff. 6/11/2023)
Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2021/126 and L.L. 2023/077.
Whenever work or materials are subject to special or progress inspection, as provided in this code, such work or materials shall be listed on the title sheet of the construction documents, or the sheet immediately following, as subject to special or progress inspection.
The application shall contain all information required to demonstrate compliance with the New York city energy conservation code. This information shall include signed and sealed construction drawings, including electrical drawings, to the extent that they demonstrate such energy code compliance, as required by such energy code and rules.
Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2009/085.
Each plan or drawing shall contain the license number, seal, signature (or equivalent as approved by the commissioner) and address of the registered design professional or landscape architect who prepared or supervised the preparation of the plans.
Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2008/008.
In addition to the data and information specified in this code and the rules of the department, the commissioner is authorized to require the submission of additional plans, surveys, computations, analyses, test reports, photographs, special inspection and such other data and information as may be necessary to determine compliance with this code and other applicable laws and rules.
The commissioner is authorized to waive the submission of any of the required construction documents and other data if review of such documents is not necessary to ascertain compliance with this code or not required for the phase of work for which a permit is sought.
Where the lowest above-grade floor or the lowest subgrade floor of a building is to be raised, lifted, elevated or moved, such work shall be listed on the title sheet of the construction documents as subject to special inspection.
The title sheet of construction documents for the following buildings shall list whether the building is exempt from the requirement to provide connections for temporary external generators pursuant to any exception contained in sections G304.5.1 or G304.5.2 of appendix G of the New York city building code, as applicable:
1. A new or substantially improved building, as such term is defined in appendix G of the New York city building code, that contains space classified in occupancy group I-1 or I-2 or space that is an adult home, enriched housing, community residence or intermediate care facility classified as occupancy group R pursuant to an exception to section 308.3.1 or 308.3.2 of the New York city building code, and that is located in a special flood hazard area, as such term is defined in appendix G of the New York city building code; and
2. A new or substantially improved building that contains space classified as an occupancy group I-2 hospital and that is located in a shaded X-Zone, as such terms are defined in appendix G of the New York city building code.
(Am. L.L. 2021/126, 11/7/2021, eff. 11/7/2022)
Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2021/126.
Loading...