801.2.2 Outlets.
The outlet shall be arranged so that the flue gases are not directed so that they jeopardize people, overheat combustible structures, or enter building openings in the vicinity of the outlet.
801.2.3 Support.
Chimneys and vents shall not be supported by the equipment they serve unless such equipment has been specifically designed for such loads.
801.2.4 Oil-fired appliances.
Oil-fired appliances shall be vented in accordance with this code and NFPA 31.
801.2.5 Gas fired appliances.
Gas fired appliances shall be vented in accordance with the New York City Fuel Gas Code.
801.3 Masonry chimneys.
Masonry chimneys shall be constructed in accordance with the New York City Building Code.
801.4 Positive flow.
Venting systems shall be designed and constructed so as to develop a positive flow adequate to convey all combustion products to the outside atmosphere.
801.5 Design.
Venting systems shall be designed in accordance with this chapter and comply with the requirements of the New York City Air Pollution Control Code.