Skip to code content (skip section selection)
Compare to:
New York City Overview
The New York City Charter
The New York City Administrative Code
The Rules of the City of New York
THE RULES OF THE CITY OF NEW YORK
Title 1: Department of Buildings
Title 2: Board of Standards and Appeals
Title 3: Fire Department
Title 6: Department of Consumer and Worker Protection
Title 9: Procurement Policy Board Rules
Title 12: Franchise and Concession Review Committee
Title 15: Department of Environmental Protection
Title 16: Department of Sanitation
Title 17: Business Integrity Commission
Title 19: Department of Finance
Title 20: Tax Appeals Tribunal
Title 21: Tax Commission
Title 22: Banking Commission
Title 24: Department of Health and Mental Hygiene
Title 25: Department of Mental Health and Retardation [Repealed]
Title 28: Housing Preservation and Development
Title 29: Loft Board
Title 30: Rent Guidelines Board
Title 31: Mayor's Office of Homelessness and Single Room Occupancy
Title 34: Department of Transportation
Title 35: Taxi and Limousine Commission
Title 38: Police Department
Title 38-A: Civilian Complaint Review Board
Title 39: Department of Correction
Title 40: Board of Correction
Title 41: Department of Juvenile Justice
Title 42: Department of Probation
Title 43: Mayor
Title 44: Comptroller
Title 45: Borough Presidents
Title 46: Law Department
Title 47: Commission on Human Rights
Title 48: Office of Administrative Trials and Hearings (OATH)
Title 49: Department of Records and Information Services
Title 50: Community Assistance Unit
Title 51: City Clerk
Title 52: Campaign Finance Board*
Title 53: Conflicts of Interest Board
Title 55: Department of Citywide Administrative Services
Title 56: Department of Parks and Recreation
Title 57: Art Commission
Title 58: Department of Cultural Affairs
Title 60: Civil Service Commission
Title 61: Office of Collective Bargaining
Title 62: City Planning
Title 63: Landmarks Preservation Commission
Title 66: Department of Small Business Services
Title 67: Department of Information Technology and Telecommunications
Title 68: Human Resources Administration
Title 69: Department of Aging
Title 70: In Rem Foreclosure Release Board
Title 71: Voter Assistance Commission
Title 72: Office of Emergency Management
Title 73: Civic Engagement Commission
Title 74: Community Hiring
Loading...
Section BC 1025: Luminous Egress Path Markings
1025.1 General.
Approved luminous egress path markings delineating the exit path shall be provided in all high-rise buildings subject to Section 403.5 having occupied floors located more than 75 feet (22 860 mm) above the lowest level of Fire Department vehicle access in accordance with Sections 1025.1 through 1025.9.
   Exceptions:
      1.   Luminous egress path markings shall not be required on the level of exit discharge in lobbies that serve as part of the exit path in accordance with Section 1028.1, Exception 1.
      2.   In open parking garages, luminous egress path markings shall not be required in open exit stairways serving only the open parking garage, and areas of open parking garages that serve such part of the exit path.
      3.   Luminous egress path markings shall not be required on egress paths serving Group R-2.
1025.2 Required markings.
Egress path markings shall be provided in interior exit stairways, interior exit ramps and exit passageways, in accordance with Sections 1025.2.1 through 1025.2.9. Entrances to interior exit stairways, interior exit ramps and exit passageways shall be provided with exit signs in compliance with Section 1025.2.6.1.
1025.2.1 Steps.
A solid and continuous stripe shall be applied to the horizontal leading edge of each step and shall extend for the full length of the step. Outlining stripes shall have a minimum horizontal width of 1 inch (25.4 mm) and a maximum width of 2 inches (50.8 mm). The leading edge of the stripe shall be placed not more than 1/2 inch (12.7 mm) from the leading edge of the step and the stripe shall not overlap the leading edge of the step by more than 1/2 inch (12.7 mm) down the vertical face of the step. Outlining stripes on steps shall comply with Figure S101.1(2) in Appendix S.
   Exception: The minimum width of 1 inch (25.4 mm) shall not apply to outlining stripes listed in accordance with UL 1994.
1025.2.2 Landings.
The leading edge of landings shall be marked with a stripe consistent with the dimensional requirements for steps. Stripes on landings shall comply with Figure S101.1(3) in Appendix S.
1025.2.3 Handrails.
Handrails and handrail extensions shall be marked with a solid and continuous stripe having a minimum width of 1 inch (25.4 mm). The stripe shall be placed on the top surface of the handrail for the entire length of the handrail, including extensions and newel post caps. Where handrails or handrail extensions bend or turn corners, the stripe shall not have a gap of more than 4 inches (101.6 mm). Stripes on handrails shall comply with Figure S101.1(4) in Appendix S.
   Exception: The minimum width of 1 inch (25.4 mm) shall not apply to outlining stripes listed in accordance with UL 1994.
1025.2.4 Perimeter demarcation lines.
Stair landings and other floor areas within interior exit stairways, interior exit ramps and exit passageways, with the exception of the sides of steps, shall be provided with solid and continuous demarcation lines on the floor or on the walls or a combination of both. The stripes shall be 1 to 2 inches (25.4 mm to 50.8 mm) wide with interruptions not exceeding 4 inches (101.6 mm).
   Exception: The minimum width of 1 inch (25.4 mm) shall not apply to outlining stripes listed in accordance with UL 1994.
1025.2.4.1 Floor-mounted demarcation lines.
Perimeter demarcation lines shall be placed within 4 inches (101.6 mm) of the wall and shall extend to within 2 inches (50.8 mm) of the markings on the leading edge of landings. The demarcation lines shall continue across the floor in front of all doors. Perimeter demarcation lines shall comply with Figure S101.1(5) in Appendix S.
   Exceptions:
      1.   Demarcation lines shall not extend in front of exit discharge doors that lead out of an exit and through which occupants must travel to complete the exit path.
      2.   Demarcation lines shall be continuous but need not extend into an area such as a dead end or an obstruction that is selected not to be outlined because it is not part of the egress path.
1025.2.4.2 Wall-mounted demarcation lines.
Perimeter demarcation lines shall be placed on the wall with the bottom edge of the stripe not more than 4 inches (101.6 mm) above the finished floor. At the top or bottom of the stairs, demarcation lines shall drop vertically to the floor within 2 inches (50.8 mm) of the step or landing edge. Demarcation lines on walls shall transition vertically to the floor and then extend across the floor where a line on the floor is the only practical method of outlining the path. Where the wall line is broken by a door, demarcation lines on walls shall continue across the face of the door or transition to the floor and extend across the floor in front of such door. Wall-mounted demarcation lines shall comply with Figure S101.1(8) in Appendix S.
   Exceptions:
      1.   Demarcation lines shall not extend in front of exit discharge doors that lead out of an exit and through which occupants must travel to complete the exit path.
      2.   Perimeter demarcation lines are not required on the sides of steps.
      3.   Perimeter demarcation lines are not required where an area such as a dead end or an obstruction is selected not to be outlined because it is not part of the egress path, the demarcation lines shall not be required in such area provided that a demarcation line is continuous across the floor.
1025.2.4.3 Transition.
Where a wall-mounted demarcation line transitions to a floor-mounted demarcation line, or vice versa, the wall-mounted demarcation line shall drop vertically to the floor to meet a complementary extension of the floor-mounted demarcation line, thus forming a continuous marking. Transitioning demarcation lines shall comply with Figure S101.1(7) in Appendix S.
1025.2.5 Obstacles.
Obstacles at or below 6 feet 6 inches (1981.2 mm) in height and projecting more than 4 inches (101.6 mm) into the egress path shall be outlined with markings not less than 1 inch (25.4 mm) in width comprised of a pattern of alternating equal bands, of luminous material and black, with the alternating bands not more than 2 inches (50.8 mm) thick and angled at 45 degrees (0.79 rad). Obstacles shall include, but are not limited to, standpipes, hose cabinets, wall projections and restricted height areas. However, such markings shall not conceal any required information or indicators including but not limited to instructions to occupants for the use of standpipes. Markings on obstacles shall comply with Figure S101.1(6) in Appendix S.
1025.2.6 Doors within the exit path.
Doors through which occupants must pass in order to complete the exit path, and doors serving horizontal exits, shall be provided with markings complying with Sections 1025.2.6.1 through 1025.2.6.3 of this chapter and Figures S101.1(11) and S101.1(12) in Appendix S. Exit discharge doors shall further comply with Section 1025.2.6.1.2.
1025.2.6.1 Emergency exit symbol.
The doors shall be identified by a low-location luminous emergency exit symbol complying with Section 1025.6.1. The exit symbol shall be not less than 4 inches (101.6 mm) in height and shall be mounted on the door itself in accordance with Section 1025.2.6.1.1. Such signs shall be no higher than 18 inches (457.2 mm) above the finished floor.
1025.2.6.1.1 Mounting location.
The vertical centerline of the sign shall be centered with the door, or shall be in that half of the door, either the right or left, that contains the latch. In case of double-doors, both doors shall be marked and the signs shall be centered with the doors. Arrows may be omitted on door-mounted signs. Door-mounted signs shall comply with Figure S101.1(1) in Appendix S.
1025.2.6.1.2 Exit discharge doors.
At doors serving as exit discharge, a sign in compliance with Section 1025.2.6.1.1 shall contain supplemental directional text such as "FINAL EXIT", "EXIT THROUGH LOBBY", or "EXIT TO STREET" in sans serif letters one-half as high as the word EXIT. Exit discharge door sign shall comply with Figure S101.1(13) in Appendix S.