Skip to code content (skip section selection)
Compare to:
New York City Overview
The New York City Charter
The New York City Administrative Code
The Rules of the City of New York
THE RULES OF THE CITY OF NEW YORK
Title 1: Department of Buildings
Title 2: Board of Standards and Appeals
Title 3: Fire Department
Title 6: Department of Consumer and Worker Protection
Title 9: Procurement Policy Board Rules
Title 12: Franchise and Concession Review Committee
Title 15: Department of Environmental Protection
Title 16: Department of Sanitation
Title 17: Business Integrity Commission
Title 19: Department of Finance
Title 20: Tax Appeals Tribunal
Title 21: Tax Commission
Title 22: Banking Commission
Title 24: Department of Health and Mental Hygiene
Title 25: Department of Mental Health and Retardation [Repealed]
Title 28: Housing Preservation and Development
Title 29: Loft Board
Title 30: Rent Guidelines Board
Title 31: Mayor's Office of Homelessness and Single Room Occupancy
Title 34: Department of Transportation
Title 35: Taxi and Limousine Commission
Title 38: Police Department
Title 38-A: Civilian Complaint Review Board
Title 39: Department of Correction
Title 40: Board of Correction
Title 41: Department of Juvenile Justice
Title 42: Department of Probation
Title 43: Mayor
Title 44: Comptroller
Title 45: Borough Presidents
Title 46: Law Department
Title 47: Commission on Human Rights
Title 48: Office of Administrative Trials and Hearings (OATH)
Title 49: Department of Records and Information Services
Title 50: Community Assistance Unit
Title 51: City Clerk
Title 52: Campaign Finance Board*
Title 53: Conflicts of Interest Board
Title 55: Department of Citywide Administrative Services
Title 56: Department of Parks and Recreation
Title 57: Art Commission
Title 58: Department of Cultural Affairs
Title 60: Civil Service Commission
Title 61: Office of Collective Bargaining
Title 62: City Planning
Title 63: Landmarks Preservation Commission
Title 66: Department of Small Business Services
Title 67: Department of Information Technology and Telecommunications
Title 68: Human Resources Administration
Title 69: Department of Aging
Title 70: In Rem Foreclosure Release Board
Title 71: Voter Assistance Commission
Title 72: Office of Emergency Management
Title 73: Civic Engagement Commission
Title 74: Community Hiring
Loading...
1009.11 Instructions.
In areas of rescue assistance and exterior areas for assisted rescue, instructions on the use of the area under emergency conditions shall be posted. Signage shall comply with the ICC A117.1 requirements for visual characters. The instructions shall include all of the following:
   1.   Persons able to use the exit stairway do so as soon as possible, unless they are assisting others.
   2.   Information on planned availability of assistance in the use of stairs or supervised operation of elevators and how to summon such assistance.
   3.   Directions for use of the two-way communications system where provided.
Section BC 1010: Doors, Gates and Turnstiles
1010.1 Doors.
Means of egress doors shall meet the requirements of this section. Doors serving a means of egress system shall meet the requirements of this section and Section 1022.2. Doors provided for egress purposes in numbers greater than required by this code shall meet the requirements of this section.
Means of egress doors shall be readily distinguishable from the adjacent construction and finishes such that the doors are easily recognizable as doors. Mirrors or similar reflecting materials shall not be used on means of egress doors. Means of egress doors shall not be concealed by curtains, drapes, decorations or similar materials.
1010.1.1 Size of doors.
The minimum width and height of each door opening shall be in accordance with this section.
1010.1.1.1 Door width.
The required capacity of each door opening shall be sufficient for the occupant load thereof and shall provide a minimum clear width of 32 inches (812.2 mm). Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees (1.57 rad). Where this section requires a minimum clear width of 32 inches (812.8 mm) and a door opening includes two door leaves without a mullion, one leaf shall provide a clear opening width of 32 inches (812.8 mm). The maximum width of a swinging door leaf shall be 48 inches (1220 mm) nominal. Means of egress doors in a Group I-2 occupancy used for the movement of beds shall provide a clear width not less than 41 1/2 inches (1054.1 mm).
   Exceptions:
      1.   The minimum and maximum width shall not apply to door openings that are not part of the required means of egress in Group R-2 and R-3 occupancies.
      2.   Door openings to resident sleeping units in Group I-3 occupancies shall have a clear width of not less than 28 inches (711.2 mm).
      3.   Door openings to storage closets less than 10 square feet (0.93 m 2 ) in area shall not be limited by the minimum width.
      4.   Width of door leaves in revolving doors that comply with Section 1010.1.4.1 shall not be limited.
      5.   In other than Group R-1 occupancies, the minimum widths shall not apply to interior egress doors within a dwelling unit or sleeping unit that is not required to be an Accessible unit, Type B+NYC or Type B unit.
      6.   Doors to walk-in freezers and coolers less than 1,000 square feet (92.9 m 2 ) in area shall have a maximum width of 60 inches (1524 mm).
      7.   In Group R-1 dwelling units or sleeping units not required to be Accessible units, the minimum width shall not apply to doors for showers or saunas.
1010.1.1.2 Projections into clear width.
There shall not be projections into the required clear width lower than 34 inches (863.4 mm) above the floor or ground. Projections into the clear opening width between 34 inches (863.4 mm) and 80 inches (2032 mm) above the floor or ground shall not exceed 4 inches (101.6 mm).
   Exception: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the floor.
1010.1.1.3 Height.
The height of doors shall be not less than 80 inches (2032 mm).
   Exceptions:
      1.   Door openings within a dwelling unit or sleeping unit shall be not less than 78 inches (1981.2 mm) in height.
      2.   Exterior door openings in dwelling units and sleeping units, other than the required exit door, shall be not less than 76 inches (1930.4 mm) in height.
1010.1.2 Door swing.
Egress doors shall be installed in accordance with this section.
1010.1.2.1 Mounting.
Egress doors shall be of the pivoted or side-hinged swinging type.
   Exceptions:
      1.   Private garages, office areas, factory and storage areas with an occupant load of 10 or less.
      2.   Group I-3 occupancies used as a place of detention.
      3.   Critical or intensive care patient rooms within suites of health care facilities.
      4.   Doors within or serving a single dwelling unit in Groups R-2 and R-3.
      5.   In other than Group H occupancies, revolving doors complying with Section 1010.1.4.1.
      6.   In other than Group H occupancies, special purpose horizontal sliding, accordion or folding door assemblies complying with Section 1010.1.4.3.
      7.   Power-operated doors in accordance with Section 1010.1.4.2.
      8.   Doors serving a bathroom within an individual sleeping unit in Group R-1.
      9.   In other than Group H occupancies, manually operated horizontal sliding doors are permitted in a means of egress from spaces with an occupant load of 10 or less.