406.1 General.
Motor-vehicle-related occupancies shall comply with Sections 406.1 through 406.8.
406.2 Definitions.
Editor's note: this section has been amended by L.L. 2024/055, 4/6/2024, eff. 12/21/2025. For related unconsolidated provisions, see Appendix A at L.L. 2024/055.
The following terms are defined in Chapter 2:
CARPORT.
MECHANICAL-ACCESS OPEN PARKING GARAGE.
OPEN PARKING GARAGE.
PRIVATE GARAGE.
RAMP-ACCESS OPEN PARKING GARAGE.
406.3 Private garages and carports.
Private garages and carports shall comply with Sections 406.3.1 through 406.3.5.
406.3.1 Classification.
Private garages and carports shall be classified as Group U occupancy.
406.3.2 Clear height.
In private garages and carports, the clear height in vehicle and pedestrian traffic areas shall be not less than 7 feet (2134 mm). Vehicle and pedestrian areas accommodating van-accessible parking shall comply with Section 1106.5.
406.3.3 Floor construction.
Private garage and carport floors shall be of concrete or equivalent noncombustible material that will not absorb flammable liquids. The area of floor used for parking of vehicles shall be sloped to facilitate the movement of liquids to a drain. The sills of all door openings connecting a dwelling unit to a private garage shall be raised at least 4 inches (102 mm) above the floor level of the garage.
Exception: Asphalt surfaces shall be permitted at ground level in carports.