701.10 Cured-in-place pipe.
Cured-in-place pipe (CIPP) and epoxy spray pipe lining systems shall not be used.
701.11 Connections.
Direct connection of a steam exhaust, blowoff or drip pipe shall not be made with the building drainage system. Wastewater when discharged into the building drainage system shall be at a temperature not higher than 150°F (65.6°C). When higher temperatures exist, approved cooling methods shall be provided.
702.1 Above-ground sanitary drainage and vent pipe.
Above-ground soil, waste and vent pipe shall conform to one of the standards listed in Table 702.1.
Material | Standard |
Material | Standard |
Acrylonitrile butadiene styrene (ABS) plastic pipe in IPS diameters, including Schedule 40, DR 22 (PS 200) and DR 24 (PS 140); with a solid, cellular core or composite wall
a | ASTM D 2661; ASTM F 628; ASTM F 1488; CSA B181.1 |
Brass pipe | ASTM B 43 |
Cast-iron pipe | ASTM A 74; ASTM A 888; CISPI 301 |
Copper or copper-alloy pipe | ASTM B 42; ASTM B 302 |
Copper or copper-alloy tubing (Type K or L) | ASTM B 75; ASTM B 88; ASTM B 251 |
Ductile iron | AWWA C151 |
Galvanized steel pipe | ASTM A 53 |
Polyvinyl chloride (PVC) plastic pipe in IPS diameters, including Schedule 40, DR 22 (PS 200), and DR 24 (PS 140); with a solid, cellular core or composite wall
a | ASTM D 2665; ASTM F 891; ASTM F 1488; CSA B181.2 |
Polyvinyl chloride (PVC) plastic pipe with a 3.25-inch O.D. and a solid, cellular core or composite wall
a | ASTM D 2949; ASTM F 1488 |
Stainless steel drainage systems, Types 304 and 316L | ASME A112.3.1 |
For SI: 1 inch = 25.4 mm.
a. Limited to residential buildings five stories or less in height.
702.2 Underground building sanitary drainage and vent pipe.
Underground building sanitary drainage and vent pipe shall conform to one of the standards listed in Table 702.2.
Material | Standard |
Cast-iron pipe | ASTM A 74; ASTM A 888; CISPI 301 |
Copper or copper alloy tubing (Type K or L) | ASTM B 75; ASTM B 88; ASTM B 251 |
Ductile iron | AWWA C151 |
Polyolefin pipe | ASTM F 1412; CSA B181.3 |
Polyvinyl chloride (PVC) plastic pipe in IPS diameters, including Schedule 40, DR 22 (PS 200), and DR 24 (PS 140); with a solid, cellular core or composite wall
a | ASTM D 2665; ASTM F 891; ASTM F 1488; CSA B181.2 |
Stainless steel drainage systems, Type 316L | ASME A112.3.1 |
For SI: 1 inch = 25.4 mm.
a. Limited to residential buildings five stories or less in height.