403.3.5 Pay facilities.
Where pay facilities are installed, such facilities shall be in excess of the required minimum facilities. Required facilities shall be free of charge.
403.3.6 Door locking.
Where a toilet room is provided for the use of multiple occupants, the egress door for the room shall not be lockable from the inside of the room. This section does not apply to family or assisted-use toilet rooms.
403.4 Signage.
Required public facilities shall be designated by a legible sign for each sex or, for a single- occupant toilet room, for all sexes. Signs shall be readily visible and located near the entrance to each toilet facility. Existing single-occupant toilet rooms shall comply with this requirement.
403.4.1 Directional signage.
Directional signage indicating the route to the required public toilet facilities shall be posted in accordance with Section 1110 of the New York City Building Code. Such signage shall be located in a lobby, corridor, aisle or similar space, such that the sign can be readily seen from the main entrance to the building or tenant space.
403.5 Drinking fountain location.
Drinking fountains shall not be required to be located in individual tenant spaces provided that public drinking fountains are located on each story within a distance of travel of 500 feet (152 m) of the most remote location in the tenant space on such story. Where the tenant space is in a covered or open mall, such distance shall not exceed 300 feet (91 m). Drinking fountains shall be located on an accessible route.
404.1 Where required.
Accessible plumbing facilities and fixtures shall be provided in accordance with the New York city building code.
404.2 Accessible fixture requirements.
Accessible plumbing fixtures shall be installed with the clearances, heights, spacings and arrangements in accordance with ICC A117.1.
404.3 Exposed pipes and surfaces.
Water supply and drain pipes under accessible lavatories and sinks shall be covered or otherwise configured to protect against contact. Pipe coverings shall comply with ASME A112.18.9.