§ 51.067 MEASUREMENTS, TESTS AND ANALYSES.
   (A)   The owner of any property serviced by a building sewer carrying industrial wastes shall provide laboratory measurements, tests and analyses of waters and wastes to illustrate compliance with this chapter and any special conditions for discharge established by the city or regulatory agencies having jurisdiction over the discharge.
   (B)   The number, type and frequency of laboratory analyses to be performed by the owner shall be as stipulated by the city, but no less than once per year the industry must supply a complete analysis of the constituents of the wastewater discharge to assure that compliance with the federal, state and local standards are being met. The owner shall report the results of measurements and laboratory analyses to the city at such times and in such manner as prescribed by the city. The owner shall bear the expense of all measurements, analyses, and reporting required by the City. At such times as deemed necessary, the city reserves the right to take measurements and samples for analysis by an outside laboratory service.
('71 Code, § 8-6-5(I))
   (C)   All measurements, tests, and analyses of the characteristics of waters and wastes to which reference is made in this chapter shall be determined in accordance with the latest edition of IEPA division of Laboratories Manual of Laboratory Methods, and shall be determined at the control manhole provided, or upon suitable samples taken at said control manhole. In the event that no special manhole has been required, the control manhole shall be considered to be the nearest downstream manhole in the public sewer to the point at which the building sewer is connected. Sampling shall be carried out by customarily accepted methods to reflect the effect of constituents upon the sewage works and to determine the existence of hazards to life, limb and property. The particular analyses involved will determine whether a 24-hour composite of all out-falls of a premises is appropriate or whether a grab sample or samples should be taken. Normally, but not always, BOD and suspended solids analyses are obtained from 24-hour composites of all outfalls, whereas pH's are determined from periodic grab samples.
('71 Code, § 8-6-5(J))
   (D)   Any person discharging wastes having concentrations greater than the normal concentrations as set forth herein shall upon notification by the approving authority install a composite sample with a compatible pacing (metering) device for monitoring said substances. The pacing and sampling devices shall be of a type approved by the Superintendent. All testing and measuring procedures for the analysis of pollutants shall be in conformance with title 40-CFR-part 136.
   (E)   The cost of all required measurements, tests and analyses shall be borne by the contributor.
('71 Code, § 8-6-5(K))