1291.04   DEVELOPMENT REQUIREMENTS.
   (a)   Number of Dwelling Units. The number of dwelling units shall be as recommended by the Planning Commission and as approved by the City Council. In no case shall the number of dwelling units be less than three, nor more than eight units.
   (b)   Landscaping. Landscaping shall be provided in the front yard and along lot lines in order to provide a measure of visual and sound privacy for residents. Fencing or plant materials may be utilized to accomplish this requirement. Fences shall comply with the requirements of Section 1286.07 . The Planning Commission shall have the discretion to recommend, and the City Council may approve, a requirement or modification of landscaping based upon the area of the parcel available for landscaping.
   (c)   Dumpsters and Trash Receptacles. Dumpsters shall not be located in the front yard, and shall be screened by a six feet high solid fence. Trash receptacles shall not be visible from the street.
   (d)   Architecture and Design.
      (1)   The architecture and design of proposed structures shall be compatible with and similar to the architecture and design of structures in the immediate vicinity where the vicinity is primarily composed of residential structures; the architecture and design of proposed structures shall be compatible with the existing architecture and design of structures in the immediate vicinity where the vicinity is primarily composed of commercial structures.
      (2)   New structures shall be required to comply with all requirements of Section 1291.04(d)(3) herein and shall not be modified; conversion or expansion of existing structures may be permitted to be modified according to the standards of Section 1291.04 (f) herein, when approved by the City Council upon recommendation of the Planning Commission.
      (3)   Proposed structures shall comply with the following:
         A.   Roof Pitch. Minimum roof pitch shall be 4/12 to 12/12, and shall be substantially similar to roof pitches in the immediate vicinity.
         B.   Dwelling Size. Dwellings shall be a minimum of 600 feet of gross floor area.
         C.   Windows. A minimum of 20 percent and a maximum of 30 percent of front and side exterior walls shall each have transparent non-reflective windows. Windows on upper stories shall be vertical with defined edges.
         D.   Exterior Building Materials. Exterior building materials facing upon a public or private street, including alleys, shall be minimum of 80 percent brick, stone, or lap siding with trim and ornamentation consisting of metal, concrete, brick, stone, or wood. In consideration of emerging technologies, the Planning Commission may recommend and the City Council may approve alternative exterior building materials that meet the intent of this chapter.
         E.   Facade Articulation. Differentiate each row house or townhouse separately with a vertical expression line. For all other multifamily buildings, provide articulation every 50 feet using windows, balconies, and a change in building materials or similar provision.
         F.   Building Entrance. For row houses or townhouses, provide one entrance per unit facing the street; for other all other multifamily buildings, provide one entrance for every 75 feet of building frontage. A sidewalk shall be provided from the existing or proposed sidewalk, or street right-of-way, to the building entrance.
         G.   Porches. Enclosed porches are permitted. Open and enclosed porches shall not be subject to Section 1286.08 (h); setbacks and design of any porches shall be as recommended by the Planning Commission and as approved by the City Council.
      (4)   Parking. One off-street parking space shall be required for each dwelling unit. This off-street space may be provided on the parcel on which the dwelling unit is located, or may be provided on a private or public off-street parking area located within 300 feet of the proposed dwelling unit according to the requirements of Section 1282.01 (b). Evidence of availability of a parking space within 300 feet of the dwelling unit shall be provided to the Zoning Administrator prior to final approval by the City Council of the rezoning to AUH-PUD.
      (5)   Applicable Regulations. With the exception of the number of dwelling units as required by Section 1291.04 (a), the City Council, upon the recommendation of the Planning Commission, may approve the lot size, lot width, setbacks, structure height, parking, landscaping, general provisions and other applicable regulations of this Zoning Code. The approval shall be based on the application of site planning criteria to achieve integration of the project with the characteristics of the surrounding area. The determination of regulations shall include the following:
         A.   Number and type of dwelling units proposed.
         B.   The integration of the proposed project with adjacent existing and future land uses, including the use of adequate landscaping.
         C.   The regulations that are required in zoning districts abutting the project.
         D.   The architecture and design of the proposed AUH-PUD.
      (6)   Signs shall be only as permitted by Chapter 1284 for residential zoning districts. The regulations for signs shall not be modified according to Section 1291.04(d)(5) herein.
(Ord. 553. Passed 7-6-21.)