Skip to code content (skip section selection)
Compare to:
Dearborn Overview
Dearborn, MI Code of Ordinances
CITY OF DEARBORN, MICHIGAN CODE OF ORDINANCES
OFFICIALS 2024
Adopting Ordinance Ordinance No. 96-661
PART I - CHARTER[1]
PART II - CODE OF ORDINANCES
Chapter 1 - GENERAL PROVISIONS
Chapter 2 - ADMINISTRATION[1]
Chapter 3 - ALCOHOLIC LIQUORS[1]
Chapter 4 - ANIMALS[1]
Chapter 5 - BUILDINGS AND BUILDING REGULATIONS[1]
ARTICLE I. - IN GENERAL
ARTICLE II. - BUILDING CODE
ARTICLE III. - STREET ADDRESS NUMBERS
ARTICLE III.5. - STORAGE, USE, MANUFACTURE, SALE, HANDLING AND TRANSPORTATION OF EXPLOSIVES
ARTICLE IV. - FENCES[2]
ARTICLE V. - EARTH CHANGING ACTIVITIES
ARTICLE VI. - BUILDING CONTRACTORS AND SUBCONTRACTORS
ARTICLE VII. - HIGH PRESSURE BOILER CODE
ARTICLE VII.5. - REFRIGERATION CODE
ARTICLE VIII. - MECHANICAL CODE
ARTICLE IX. - HEATING CODE
DIVISION 1. - GENERALLY
DIVISION 2. - LICENSES
DIVISION 3. - BOARD OF SAFETY ENGINEERS
DIVISION 4. - FEES
DIVISION 5. - BOARD OF APPEALS
DIVISION 6. - INSPECTOR
DIVISION 7. - PERMITS
DIVISION 8. - BOILERS
DIVISION 9. - HEATING SYSTEM
DIVISION 10. - VENTILATING AND AIR CONDITIONING
DIVISION 11. - STOKERS
DIVISION 12. - OIL BURNERS
DIVISION 13. - GAS BURNER INSTALLATIONS
Sec. 5-1056. - Definitions.
Sec. 5-1057. - Conformity required.
Sec. 5-1058. - Permit required.
Sec. 5-1059. - Application for permit.
Sec. 5-1060. - Approval of permit application.
Sec. 5-1061. - Installation of used gas burners, procedure required.
Sec. 5-1062. - Ventilation.
Sec. 5-1063. - Flues - Generally.
Sec. 5-1064. - Same - Installation.
Sec. 5-1065. - Same - Corrosive-resistant materials.
Sec. 5-1066. - Same - Support, location.
Sec. 5-1067. - Same - Relocation.
Sec. 5-1068. - Same - Replacement.
Sec. 5-1069. - Same - Adjustable damper.
Sec. 5-1070. - Same - Dampers permanently kept open.
Sec. 5-1071. - Draft hood - Installation.
Sec. 5-1072. - Same - Location.
Sec. 5-1073. - Same - Alternate location.
Sec. 5-1074. - Same - Revertible type.
Sec. 5-1075. - Area of flue pipe, draft hood.
Sec. 5-1076. - Baffles not to be used.
Sec. 5-1077. - Heating surfaces.
Sec. 5-1078. - Gastight.
Sec. 5-1079. - Doors.
Sec. 5-1080. - Installation - Generally.
Sec. 5-1081. - Same - Location.
Sec. 5-1082. - Same - Accessible for cleaning.
Sec. 5-1083. - Same - Combustion control.
Sec. 5-1084. - Same - Air shutter adjustment.
Sec. 5-1085. - Same - Secondary air openings.
Sec. 5-1086. - Same - Controls.
Sec. 5-1087. - Pilots - Required.
Sec. 5-1088. - Same - Fixed in stationary position.
Sec. 5-1089. - Same - Accessible.
Sec. 5-1090. - Same - Connection of lines.
Sec. 5-1091. - Same - Thermostatic safety.
Sec. 5-1092. - Shut-off valve - Required.
Sec. 5-1093. - Same - Location.
Sec. 5-1094. - Electric control valves.
Sec. 5-1095. - Gas pressure regulators.
Sec. 5-1096. - Safety devices - Required.
Sec. 5-1097. - Same - Independent of shut-off main gas supply.
Sec. 5-1098. - Low water cutoff.
Sec. 5-1099. - Forced primary air control.
Sec. 5-1100. - Piping in line direct from meter.
Sec. 5-1101. - Adjustment of pilot and burners.
Sec. 5-1102. - Pilot operation - Generally.
Sec. 5-1103. - Same - Flames not to be extinguished.
Sec. 5-1104. - Same - Luminous flame.
Sec. 5-1105. - Electrical devices, approval.
Sec. 5-1106. - Summer cooling.
Sec. 5-1107. - Flame - Regulation.
Sec. 5-1108. - Same - Not to flash.
Sec. 5-1109. - Same - Not to burn in mixer.
Sec. 5-1110. - Appliance operation, oxygen concentration pressure.
Sec. 5-1111. - Appliance - Method of test.
Sec. 5-1112. - Same - Checked by inspector and installer.
Sec. 5-1113. - Instructions to the customer - Required.
Sec. 5-1114. - Same - Printed and posted.
Secs. 5-1115 - 5-1129. - Reserved.
ARTICLE X. - ELECTRICAL CODE
ARTICLE XI. - PLUMBING CODE
ARTICLE XII. - SIGNS[6]
ARTICLE XIII. - FLOOD DAMAGE PREVENTION
ARTICLE XIV. - PROPERTY MAINTENANCE CODE
ARTICLE XV. MEDICAL AND RECREATIONAL MARIJUANA CULTIVATION AND POSSESSION
Chapter 6 - CABLE TELECOMMUNICATIONS[1]
Chapter 7 - COMMUNITY DEVELOPMENT[1]
Chapter 8 - ELECTIONS[1]
Chapter 9 - FEES FOR PERMITS AND INSPECTIONS[1]
Chapter 10 - FIRE PREVENTION AND PROTECTION[1]
Chapter 11 - OCCUPANCY AND BUILDING STANDARDS[1]
Chapter 12 - LICENSES AND BUSINESS REGULATIONS[1]
Chapter 13 - NUISANCES[1]
Chapter 14 - OFFENSES[1]
Chapter 15 - PARKS AND RECREATION[1]
Chapter 16 - SOLID WASTE[1]
Chapter 17 - STREETS, SIDEWALKS AND OTHER PUBLIC PLACES[1]
Chapter 17.5 - SUBDIVISIONS
Chapter 18 - TRAFFIC AND MOTOR VEHICLES[1]
Chapter 19 - WATER AND SEWERS[1]
Chapter 20 TRANSITION FOLLOWING AN ELECTION
A. - Cablevision Industries
B. - Ameritech New Media, Inc.
SUPPLEMENT HISTORY TABLE
STATE LAW REFERENCE TABLE MICHIGAN STATUTES ANNOTATED
STATE LAW REFERENCE TABLE - MICHIGAN COMPILED LAWS
CODE COMPARATIVE TABLE - ORDINANCES
ZONING ORDINANCE
Loading...
Sec. 5-1036. - Pilot light.
   Gas pilot, acetylene or any other gas possessing a wider range of explosiveness in a mixture with air and coal gas, or water gas, is prohibited for use in the gas pilot of any fuel oil burner.
(Ord. No. 81-65, § 10.71, 11-4-81)
Sec. 5-1037. - Fire extinguisher required.
   In the single residences, every oil burner installation shall have near the entrance to the furnace room, and readily accessible for convenient use in emergency, a hand fire extinguisher of at least a quart capacity, approved by the National Board of Fire Underwriters for extinguishing combustible oil fires; provided, however, that installations of oil burning equipment in multiple dwellings, commercial establishments of any kind or description where the public congregates or persons are permitted to be present on invitation or otherwise, such installations shall have accessible in the furnace room for immediate and convenient use in emergency, a fire extinguisher of at least 2½-gallon capacity, approved by the National Board of Fire Underwriters, and which shall be foam type or its equivalent; provided further, that in case of great hazard or danger to the public, the chief of the fire department may, in writing, require further or additional fire extinguishing apparatus in order to safeguard public property and life.
(Ord. No. 81-65, § 10.72, 11-4-81)
Secs. 5-1038—5-1055. - Reserved.
DIVISION 13. - GAS BURNER INSTALLATIONS
Sec. 5-1056. - Definitions.
   The following words, terms and phrases, when used in this division, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning:
   Gas burner shall mean a device for the final conveyance of the gas, or a mixture of gas and air, to the combustion zone of a conversion gas burner, gas fired unit heater or water radiator, gas fired boiler, heater or furnace used in connection with a space heating system.
   Gas burner equipment shall include gas burners and all piping including supply piping from meter to appliance shutoff valve, blowers, control device and accessories connected to the burners.
(Ord. No. 81-65, § 11.2, 11-4-81)
Cross reference— Definitions and rules of construction generally, § 1-2.
Sec. 5-1057. - Conformity required.
   The construction, arrangement and manner of installation of all gas burners and gas burner equipment hereafter installed for use in connection with heating systems, and the alteration and repair hereafter of all gas burners and gas burner equipment used or to be used in connection with heating systems, shall conform to the provisions of this division.
(Ord. No. 81-65, § 11.1, 11-4-81)
Sec. 5-1058. - Permit required.
   It shall be unlawful for any person or his agents to install any gas burner until an application for a permit shall have been filed with and a permit issued by the department of building and safety.
(Ord. No. 81-65, § 11.3, 11-4-81)