15.02.090 Amendment - Section 105.2 - Exempt work.
   Work Exempt from Permit. Exemptions from the permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of this code or any other laws or ordinances of this jurisdiction. A building permit shall not be required for the following:
   Building:
      1.   One-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided the floor area does not exceed 120 square feet.
      2.   Fences not over three (3) feet high.
      3.   Oil derricks.
      4.   Retaining walls that are not over two (2) feet in height measured from the top of the footing to the top of the wall, unless supporting a surcharge or any superimposed load other than the natural fill of level earth or impounding Class I, II, or IIIA liquids.
      5.   Water tanks supported directly upon grade if the capacity does not exceed 5,000 gallons and the ratio of height to diameter or width does not exceed 2 to 1.
      6.   Platforms, walks and driveways not more than 30 inches above adjacent grade, and not over any basement or story below and are not part of an accessible route.
      7.   Painting, papering, tiling, carpeting, cabinets, countertops and similar finish work.
      8.   Temporary motion picture, television and theater stage sets and scenery.
      9.   Prefabricated swimming pool accessory to a Group R-3 Occupancy that are less than 24 inches deep, do not exceed 5,000 gallons and are installed entirely above ground.
      10.   Shade cloth structures constructed for nursery or agricultural purposes, not including service systems.
      11.   Swings and other playground equipment accessory to detached one- and two-family dwellings.
      12.   In Group R-3 and U occupancies, window awnings that do not project more than 54 inches from the exterior wall, when supported by an exterior wall and do not require additional support.
      13.   Nonfixed and movable fixtures, cases, racks, counters and partitions not over 5 feet 9 inches in height.
      14.   Wood-framed decks accessory to single family dwellings where the deck is no greater than 200 square feet in area, with a walking surface that is not more than 30 inches above grade at any point, is not attached to a dwelling and does not serve as a required path of egress or accessible path of travel. Decks located in a front yard setback shall comply with the requirements in Corona Municipal Code Chapter 17.64.
      15.   Historic markers no greater than 4 feet in height measured from the adjacent finish grade to the top of the structure placed pursuant to Chapter 17.63 of the Corona Municipal Code
   Electrical:
      1.   Repairs and maintenance: Minor repair work, including the replacement of lamps or the connection of approved portable electrical equipment to approved permanently installed receptacles.
      2.   Radio and television transmitting stations: The provisions of this code shall not apply to electrical equipment used for radio and television transmissions but do apply to equipment and wiring for a power supply and the installations of towers and antennas.
      3.   Temporary testing systems: A permit shall not be required for the installation of any temporary system required for the testing or servicing of electrical equipment or apparatus.
   Gas:
      1.   Portable heating appliances
      2.   Replacement of any minor part that does not alter approval of equipment or make such equipment unsafe.
   Mechanical:
      1.   Portable heating appliance.
      2.   Portable ventilation equipment.
      3.   Portable cooling unit.
      4.   Steam, hot or chilled water piping within any heating or cooling equipment regulated by this code.
      5.   Replacement of any part that does not alter its approval or make it unsafe.
      6.   Portable evaporative cooler.
      7.   Self-contained refrigeration system containing 10 pounds or less of refrigerant and actuated by motors of 1 horsepower or less.
   Plumbing:
      1.   The stopping of leaks in drains, water, soil, waste or vent pipe, provided, however, that if any concealed trap, drainpipe, water, soil, waste or vent pipe becomes defective and it becomes necessary to remove and replace the same with new material, such work shall be considered new work and a permit shall be obtained and inspection made as provided in this code.
      2.   The clearing of stoppages or the repairing of leaks in pipes, valves or fixtures and the removal and reinstallation of water closets, provided such repairs do not involve or require the replacement or rearrangement of valves, pipes, or fixtures.
      3.   The installation of water-conserving plumbing fixtures as replacements for existing plumbing fixtures shall not, alone, require a permit or inspection from the Building Division. The replacement plumbing fixtures shall comply with Chapters 15.05 and 15.20 of this code.
   Grading:
      1.   Grading requirements and permits shall be as required by Chapter 15.36 of the Corona Municipal Code.”
(Ord. 3357 § 2 (part), 2022; Ord. 3306 § 2 (part), 2019; Ord. 3251 § 2 (part), 2016; Ord. 3159 § 2 (part), 2013; Ord. 3059 § 2 (part), 2010.)