(A) Double swing gates shall be installed so that the swivel points are outside of the opening area of the enclosure. Swivel points shall be attached to concrete filled steel posts/columns at ends of walls. Gates may be made of sheet metal, or other materials if more suitable to the architectural motif, but shall be attached to a steel tube frame painted with zinc chromate primer and medium oil alkyd paint to conform to surrounding architectural features.
(B) Enclosure area shall be set on level four inch P.C.C. pad at ground level. The areas between the pad and pick-up area shall be paved and shall not exceed a grade of 4%. Additionally, trash enclosures shall not accept drainage from adjoining areas and drains shall not be located within the trash enclosure pad areas.
(C) In industrial areas where enclosures are not visible from a public street, chain link gates with slats may be used.
(D) The Planning Department may require additional architectural features to be added to the standard design of a trash enclosure structure in order for the trash enclosure to remain architecturally compatible with the buildings within a commercial, business park, or multi-family residential facility.
(`78 Code, § 17.79.060.) (Ord. 2794 § 1 (part), 2005; Ord. 2046 § 1 (part), 1991.)