(a) Where Required within the Central Business District | Street frontages | Required |
Alleys, Ways & Courts frontages | Not required | |
(b) Height | Height of Liner Building shall be equal to or greater than the Height of the structured parking building. | |
(c) Width | Ground floor: The Liner Building shall at minimum equal the width of the parking it screens, less the permitted vehicular access points. Upper floors: The Liner Building shall at minimum equal the width of the structured parking building. | |
(d) Depth | Depth of Liner Building shall be a minimum of 15'. | |
(e) Active Uses | Required along 70% of all frontages not designated as an alley. | |
(f) First Story Glazing, non-residential Liner Buildings, all Frontages except Alleys | 70% min. of Building Frontage between 2'6" and 7'6" above grade shall be transparent windows and doors. | |
(g) First Story Glazing, residential Liner Buildings, all Frontages except Alleys | 30% min. of Building Frontage between 3' and 8' above grade shall be transparent windows and doors. | |
(h) Parking and service access | Street frontages | Max. openings per frontage: 1 Max. opening width: 24' Max. opening height for parking entrance: 11' Max. opening height for service access: 14' Continuous at-grade sidewalk and apron required |
Alleys, Ways & Courts frontages | Unlimited | |
(i) Valet zones | Shall not reduce existing sidewalk width, or shall maintain 8' min. through pedestrian sidewalk zone. | |
"Liner Building" shall have the same meaning as provided in Section 348.01.