15-24-570 Paint mixing, spraying and japanning room.
   Every paint-mixing room, paint-spraying room and every room containing a japanning dip tank, vat or japanning oven located in any building other than a building of Type IA, IB or IIA construction which is also equipped throughout with an automatic sprinkler system, shall be constructed in accordance with the requirements of this section. Any such room, with a floor area of not more than 600 square feet, shall have a floor of any type of construction permitted for the building in which located and shall have both walls and ceiling of one-hour fire-resistive construction. Any such room, with a floor area of more than 600 square feet and not more than 1,200 square feet, may have a floor of any type of construction permitted for the building in which located, and shall have both walls and ceiling of two-hour fire-resistive construction. Any such room with a floor area of more than 1,200 feet, shall be separated from every other part of the building by not less than four-hour fire-resistive construction. No such rooms shall have any opening except a doorway or doorways between such room and any part of the building. Every doorway through any such wall or separation shall be provided with a door of the character required by Chapter 14B-7 for fire doors. Nothing in this section shall be constructed as prohibiting or preventing the installation of noncombustible piping or conveyors or similar dust-tight enclosed mechanical devices between floors or stories in such rooms or buildings.
(Prior code § 129.1-49; Amend Coun. J. 10-7-20, p. 21791, Art. VI, § 39)
15-24-580 Exemptions from regulations.
   All paint-spraying operations, except maintenance, decorating or construction painting of buildings proper, shall comply with all applicable provisions of this Code and with the special provisions of Sections 15-24-590 to 15-24-670 of this Code.
(Prior code §  129.1-50)
15-24-590 Spray booths and rooms, where required.
   A spray booth shall be required when paint- spraying operations are carried on in any building when using more than one gallon of previously defined liquid in any 24-hour period except in those cases where the physical size of the materials being sprayed, such as in structural steel shop coating and similar operations, makes it impractical to conduct such operations within a spray booth. A paint-spraying room shall be required when the liquids used, as defined in Section 15-24-550, exceed ten gallons in any 24-hour period unless conducted in an approved booth. Nothing in this section shall be construed as prohibiting more than one such spray booth in any paint-mixing room.
(Prior code §  129.1-51)