(a) In every building or other structure, or part thereof, used for mercantile industrial or storage purposes, the loads approved by the building commissioner shall be marked on placards of approved design. Such placards shall be supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate. Application of such placard shall be accompanied by a certification from a registered architect or registered structural engineer that he personally inspected the building and that he computed the safe load in conformity with the provisions of this ordinance. Duplicate placards may be issued to replace lost or destroyed placards without such certification upon payment of a fee in accordance with Section 13-32-320 of this Code, where the department of buildings has records of the safe floor load limits of particular buildings.
(b) Exceptions – Posting for floor loads shall not be required in buildings or portions thereof used exclusively for the production and distribution of electricity, gas or steam.
(c) Spaces in garages and parking facilities designed for the use of passenger automobiles only shall be placarded as follows: “This floor to be used for the storage of passenger automobiles only.”
(Prior code § 68-2.12; Added Coun. J. 11-29-89, p. 8387; Amend Coun. J. 9-13-89, p. 4604; Amend Coun. J. 3-5-03, p. 104990, § 20; Amend Coun. J. 11-13-07, p. 14999, Art. II, § 1)
The building owner shall ensure that a live load greater than that for which a floor or roof is approved by the Building Commissioner shall not be placed, or caused or permitted to be placed, on any floor or roof of a building or other structure.
(Prior code § 68-2.13; Added Coun. J. 11-29-89, p. 8387; Amend Coun. J. 9-13-89, p. 4604; Amend Coun. J. 3-5-03, p. 104990, § 20; Amend Coun. J. 11-13-07, p. 14999, Art. II, § 1; Amend Coun. J. 11-9-16, p. 36266, § 13)
Permitted reduction in live loads shall comply with the provisions of subsections (a), (b) and (c) of this section.
(a) Permitted Reductions in Floor Construction. Beams, girders and trusses shall be designed to carry not less than the following percentage of the live floor loads established in Section 13-52-090 or based on the tributary floor area and influence area carried by the members.
1. For live loads of 100 pounds per square foot or less:
Tributary Area In Square Feet | Influence Area | Percentage of Live Load |
less than 200 | 400 | 100 |
300 | 600 | 86 |
400 | 800 | 78 |
600 | 1,200 | 68 |
800 | 1,600 | 63 |
greater than 800 | greater than 1,600 | 60 |
2. Linear interpolation between tabulated percentage of live loads is permitted.
3. For live loads that exceed 100 pounds per square foot no reduction is permitted.
4. No reduction is allowed for areas to be occupied as places of public assembly, garages or parking facilities, one way slabs or joists.
(b) Permitted reductions in bearing walls, columns, piers and other members supporting more than one floor shall be based on the tributary area and influence area carried by the member.
1. For live loads of 100 pounds per square foot or less:
Tributary Area In Square Feet | Influence Area | Percentage of Live Load |
less than 200 | 800 | 100 |
300 | 1,200 | 68 |
400 | 1,600 | 63 |
600 | 2,400 | 56 |
800 | 3,200 | 52 |
900 and greater | 3,600 and greater | 50 |
2. Linear interpolation between tabulated percentage of live loads is permitted.
3. No reduction is allowed for areas to be occupied as places of public assembly or for roofs. For garages and parking facilities see (4).
4. For live loads that exceed 100 pounds per square foot, and in garages and parking facilities for passenger vehicles only, members supporting more than one floor may be designed to carry not less than 80 percent of the live loads established in Section 13-52-090.
(c) Tributary Area/Influence Area. The influence area is defined as that floor area over which the influence surface for structural effects is significantly different from zero. For columns this is four times the traditional tributary area, while for flexural members it is two times. For an interior column, for instance, the influence area is the total area of the four surrounding bays, while for an interior girder it is the total area of the two contributing bays. Edge columns and girders have half the influence area of the respective interior members (two days for columns, one for girders), while a corner column has an influence area of one bay. For unusual plan configurations, the concept of significant influence effect should be applied. For multiple floors, areas for members supporting more than one floor are summed.
(Prior code § 68-2.14; Added Coun. J. 11-29-89, p. 8387)
Wind load, snow load and rain load are environmental loads. Live loads on a roof are those produced (1) during maintenance by workers, equipment and materials. Reductions in roof live loads and/or environmental roof loads shall not be permitted. Design roof loads shall be determined by the provisions of Sections 13-52-230 to 13-52-290 inclusive, 13-52-350 and 13-52-380.
(Prior code § 68-3; Added Coun. J. 11-29-89, p. 8387; 6-14-95, p. 2841)
Roofs used for roof gardens or assembly purposes shall be designed for a minimum live load of 100 pounds per square foot. Roofs used for other special purposes shall be designed for appropriate loads, as directed or approved by the building commissioner.
(Prior code § 68-3.2; Added Coun. J. 11-29-89, p. 8387; Amend Coun. J. 9-13-89, p. 4604; Amend Coun. J. 3-5-03, p. 104990, § 20; Amend Coun. J. 10-1-03, p. 9163, § 4.5; Amend Coun. J. 11-13-07, p. 14999, Art. II, § 1)