Members, supporting wall facing which is not more than four and one-half inches in thickness and securely anchored or bonded to backing, shall not be required to be fire protected, provided that such members are properly supported by spandrel beams or lintels which are fire protected as required in Section 13-60-100.
(Prior code § 49-9.4)
In buildings of business, mercantile, industrial and storage occupancies, mezzanine floors and the supports thereof of noncombustible materials shall not be required to be fire protected; provided, that the aggregate area of such mezzanines shall not exceed ten percent of the floor area in the first story nor five percent of the floor area in any other story.
(Prior code § 49-9.5)
In all buildings more than two stories and attic in height of Types III-B, III-C, and IV-A construction, all basement columns and basement bearing walls shall be of noncombustible materials or of heavy timber construction.
(Prior code § 49-10.1)
(a) Except in single-family and two-family dwellings, floor construction over basements shall provide fire resistance of not less than one hour.
(b) In buildings of Types III-B, III-C, IV-A and IV-B construction, fire protection shall not be required for floor construction over unexcavated spaces below the first floor, nor for floor construction over basements in single-family dwellings.
(Prior code § 49-10.3)