Skip to code content (skip section selection)
Compare to:
Toledo Overview
Toledo Municipal Code
TOLEDO MUNICIPAL CODE
CERTIFICATION
ADOPTING ORDINANCE
EDITOR'S NOTE
COMPARATIVE SECTION TABLE
CHARTER OF THE CITY OF TOLEDO, OHIO
PART ONE - ADMINISTRATIVE CODE
PART THREE - TRAFFIC CODE
PART FIVE - GENERAL OFFENSES CODE
PART SEVEN - BUSINESS REGULATION CODE
PART NINE - STREETS, UTILITIES AND PUBLIC SERVICES CODE
PART ELEVEN - PLANNING AND ZONING CODE
PART TWELVE - DEVELOPMENT CODE
PART THIRTEEN - BUILDING CODE
PART FIFTEEN - FIRE PREVENTION CODE
PART SEVENTEEN - HEALTH CODE
PART NINETEEN - TAXATION CODE
PART TWENTY-ONE - PERSONNEL RELATIONS AND MUNICIPAL EMPLOYMENT
CHAPTER 1106
Intensity and Dimensional Standards
1106.0100   Intensity and dimensional standards tables.
1106.0200   Measurements, computations and exceptions.
1106.0300   Multiple buildings on lot.
1106.0400   Multi-dwelling lot area bonuses and amenities in CM and CD Districts.
1106.0700   Planned Business/Industrial Park District additional standards.
1106.0800   Parks and Open Space District intensity and dimensional standards.
1106.0900   Institutional Campus District intensity and dimensional standards.
1106.0100 Intensity and dimensional standards tables.
1106.0101 Residential Districts.
   Unless otherwise expressly stated, all buildings in Residential (R) Districts must comply with the following standards, as well as all other applicable standards of this Zoning Code.
(Ord. 170-04. Passed 3-23-04; Ord. 346-10. Passed 6-22-10; Ord. 229-13. Passed 4-30-13; Ord. 533-24. Passed 10-23-24.)
Standard
RS 12
RS 9
RS 6
RD 6
RM 12
RM 24
RM 36
RMH
Standard
RS 12
RS 9
RS 6
RD 6
RM 12
RM 24
RM 36
RMH
Minimum Lot Area (sq. ft. per unit)
 
 
 
 
 
 
 
 
   Detached House
12,000
9,000
6,000
6,000
6,000
6,000
6,000
NA
   Attached House
NA
NA
NA
3,000
3,000
3,000
3,000
NA
   Duplex
NA
NA
NA
3,000
3,000
3,000
3,000
NA
   Multi-Dwelling [8]
NA
NA
NA
NA
3,600
1,800
1,200
NA
   Manufactured Home [1]
NA
NA
NA
NA
NA
NA
NA
3,600
   All Other Development
12,000
9,000
6,000
6,000
6,000
6,000
6,000
NA
Maximum Density (dwelling units per acre) [2]
3
4
6
6
10
20
30
10
Minimum Lot Width (feet)
75
60
50
50
50[3]
50[3]
50[3]
40
Minimum Setbacks (feet)
 
 
 
 
 
 
 
 
   Front
35
30
25
25
25
25
25
25[4]
   Side (one side/combined)
7.5/16
6/14[5]
5/12[5]
5/12[5]
5/12[5]
5/12[5][6]
5/12[5][6]
10/20
   Rear
35
30
25
25
25
25
25
12[7]
Maximum Height (feet)
35
35
35
35
35
35
50
20
 
NA = Not Applicable
Table Notes
[1]   The standards apply to manufactured homes in manufactured housing parks.
[2]   These density standards apply only to cluster housing, Sec. 1104.0500, and to Multiple Buildings on Lot, Sec. 1106.0300, unless otherwise expressly stated.
[3]   Minimum lot width for attached house: 25 feet.
[4]   Where a lot in a manufactured housing park abuts a dedicated place, the minimum front setback is 7 feet.
[5]   Combined total setbacks for attached houses, detached houses and duplexes may be reduced to 10 feet to accommodate an attached garage or carport.
[6]   Minimum side setback is increased to 10 feet when adjacent to RS or RD district.
[7]   Where a lot in a manufactured housing park abuts the periphery of the development, the minimum rear setback is 25 feet. No structure in a manufactured housing park may be located in the required rear setback.
[8]   These density standards apply to single buildings, for multiple buildings on a lot see Max. Density Row and Table Note [2].
Loading...