9-2-3: UTILITY DISCONNECTION:
All utilities connected to a building or structure shall be disconnected as follows:
   A.   Sewer: Sewer laterals which meet the existing requirements of the city standards, and will be used for a future structure, shall be cut back to a point ten feet (10') inside the property line, an approved plug shall be placed in the lateral and a two inch by 4 inch (2" x 4") piece of treated lumber shall be placed at the end of the pipe and extended up to within one foot (1') of final grade. Laterals which do not meet the requirements of the city standards, or will not be used for a future structure, shall be removed back to the sewer main and the main repaired to meet the requirements of the Sunset City Public Works Department.
   B.   Culinary Water: Culinary water laterals which meet the existing requirements of the city standards, and will be used for a future structure, shall be cut back to a point ten feet (10') inside the property line, an approved plug shall be placed in the lateral and a two inch by 4 inch (2" x 4") piece of treated lumber shall be placed at the end of the pipe and extended up to within one foot of final grade. Laterals which do not meet the requirements of the City Standards, or will not be used for a future structure, shall be removed back to the water main and the main repaired to meet the requirements of the Sunset City Public Works Department.
   C.   Storm Water: Storm water laterals which meet the existing requirements of the city standards, and will be used for a future structure, shall be cut back to a point ten feet (10') inside the property line, an approved plug shall be placed in the lateral and a two inch by 4 inch (2" x 4") piece of treated lumber shall be placed at the end of the pipe and extended up to within one foot of final grade. Laterals which do not meet the requirements of the city standards, or will not be used for a future structure, shall be removed back to the storm water main and the main repaired to meet the requirements of the Sunset City Public Works Department.
   D.   All utility laterals being capped or removed to the main shall be inspected by the Public Works Department before being covered.
(Ord. 2020-02, 5-19-2020)