(A) All exterior boundary monuments shall be of new galvanized iron pipe of not less than 1½ inches in diameter and 18 inches in length. Center line monuments shall be of new galvanized iron pipe not less than 1½ inches in diameter and 15 inches in length. At all minor (60 feet or less) street intersections and/or locations designated by the public works director, center line monuments shall be constructed to the requirements of the City of Oxnard Standard Plate 2D (Type A) and at all major (greater than 60 feet) street intersections and/or locations designated by the director of public works, center line monuments shall be constructed to the requirements of the City of Oxnard Standard Plate 2D (Type B) in lieu of monuments constructed to the standards otherwise specified in this section. All lot corner monuments shall be of new galvanized iron pipe of not less than ½-inch in diameter and 15 inches in length or a cross-cut in concrete. Front lot corners shall be a cross-cut (or other suitable monument) in the sidewalk any designated distance from the true corner on the side lot line extended.
(B) The engineer or surveyor shall also provide proper ties to the location of all center line monuments and these ties shall be shown on a tie sheet in a form approved by the director of public works. A minimum of three such ties shall be required for each monument. Tie notes shall be on file in the office of the city engineer prior to the acceptance of the improvements into the city road system.
(`64 Code, Sec. 27-87.2) (Ord. No. 1772, 1998)