The owner shall construct all necessary sanitary sewers, including manholes, house laterals and other incidentals, according to City standards.
All trenches under the paved areas shall be backfilled to the finish grade with sand, gravel or screenings, unless otherwise directed by the City Engineer.
No plat showing subdivision of a parcel of land into two or more smaller parcels and intended for residential, commercial or industrial structures which are so located as to require individual sewage disposal systems shall be approved by the City authorities until investigated and approved by the Health Commissioner or his authorized agent; and no building permit shall be issued until a percolation test has been submitted to and approved by the Health Commissioner or his authorized agent. (Ord. 1961-3. Passed 7-31-61.)
The owner shall construct concrete sidewalks, four feet in width and four inches in thickness, on both sides of the street the full length of the project, including street intersections. All walks shall be constructed according to City standards and at the location and grade indicated on the approved construction plans. (Ord. 1961-3. Passed 7-31-61.)
Grading of the entire area of the subdivision shall be done with regard to the natural drainage of the area involved, and open ditches, conduits, catch basins, inlets and manholes of adequate size as approved by the City Engineer shall be constructed to provide for such drainage.
Subgrade drainage, as directed by the City Engineer, shall be provided for the drainage of the subgrade beneath all paved areas.
All storm drains crossing beneath the paved areas shall be of reinforced concrete or an approved equal in strength and durability.
All trenches under the paved areas shall be backfilled with sand, gravel or screenings, unless otherwise directed by the City Engineer.
Downspout tile shall be connected to the storm sewers where storm sewers are available. Lot drainage shall be done in accordance with City standards.
(Ord. 1961-3. Passed 7-31-61.)
All underground gas, telephone and electric lines shall be so designed and constructed as to avoid conflict with the water and sewer lines.
All trenches under the paved areas shall be backfilled with sand, gravel or screenings, unless otherwise directed by the City Engineer.
Poles for aboveground utilities shall be located on rear property lines as near as possible. (Ord. 1961-3. Passed 7-31-61.)
The owner shall furnish and erect street name signs at all street intersections within the subdivision. The minimum requirements for the signs shall be eighteen gauge, baked enamel, four inches by twenty-four inches, with three-inch letters, erected on two-inch galvanized, wrought iron pipe posts driven thirty inches into the ground and extending eight feet above ground.