18-29-1003.10 Bottling establishments.
   Bottling plants shall discharge process wastes into an interceptor that will provide for the separation of broken glass or other solids before discharging waste into the drainage system.
18-29-1003.11 Slaughterhouses.
   Slaughtering room and dressing room drains shall be equipped with approved separators. The separator shall prevent the discharge into the drainage system of feathers, entrails and other materials that cause clogging.
18-29-1003.12 Venting of interceptors and separators.
   Interceptors and separators shall be designed so as not to become air bound. Each interceptor or separator shall be vented in accordance with one of the methods in Article 9.
(Amend Coun. J. 10-14-21, p. 37722, Art. X, § 3)
18-29-1003.13 Access and maintenance of interceptors and separators.
   Access shall be provided to each interceptor and separator for service and maintenance. Interceptors and separators shall be maintained by periodic removal of accumulated grease, scum, oil, or other floating substances and solids deposited in the interceptors or separators as often as necessary to ensure efficient operation. Each owner shall keep a written record of all maintenance of the interceptor or separator for the life of the unit, or for a period of five years, whichever is longer. Such record of maintenance shall be made available for review by the department of buildings and the department of water management or their duly authorized representatives. The written record of maintenance shall also be transmitted to the department of buildings or the department of water management, as prescribed by the department, upon request.
(Amend Coun. J. 7-29-15, p. 3537, § 4)
18-29-1004 Materials, Joints and Connections.
18-29-1004.1 General.
   The materials and methods utilized for the construction and installation of traps, interceptors and separators shall comply with this chapter and the applicable provisions of Article 7. The fittings shall not have ledges, shoulders or reductions capable of retarding or obstructing flow of the piping.