Electrostatic paint spray and deterring apparatus shall conform to the requirements of Chapter 15-24 for the provisions of paint spraying and to the specific requirements of the following:
(a) Electrostatic apparatus and devices used in connection with paint-spraying and paint-deterring operations shall be only of the approved type.
(b) Transformers, power packs, control apparatus and all other electrical portions of the equipment, with the exception of high voltage grids and electrostatic atomizing heads and their connections, shall be located outside of the spraying areas or vapor areas as defined in Section 15-24-550 or shall comply with the requirements of Section 14E-5-500 for Class II hazardous locations.
(c) Electrodes and electrostatic atomizing heads shall be of substantial construction, shall be rigidly supported in permanent locations and shall be effectively insulated from ground. Insulators shall be nonporous and noncombustible.
(Prior code § 129.1-60; Amend Coun. J. 9-6-17, p. 55278, Art. II, § 54)