Water heating equipment must be properly installed and maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower, and laundry facility at a minimum temperature of 110ºF (43ºC). Adequate combustion air must be provided for all gas-fired water heaters. All water heaters must be equipped and maintained with a combination temperature and pressure-relief valve and a relief valve discharge pipe.
Grease interceptors and automatic grease removal devices must be maintained in accordance with this code and the manufacturer’s instructions. Grease interceptors and automatic grease removal devices must be regularly serviced and cleaned to prevent the discharge of oil, grease, and other substances harmful or hazardous to the building drainage system, the public sewer, the private sewage disposal system, or the sewage treatment plant or processes. Records of maintenance, cleaning, and repairs must be available for inspection by the building official.