The provisions of Section 2406 of IBC are adopted by reference with the following modifications:
1. Revise exception 1 to Section 2406.3 to read:
"1. For other than tempered glass, manufacturer’s designations are not required where the use of a certificate, affidavit or other evidence confirming compliance with this code is approved by the building official."
2. Revise exception 4 to Section 2406.4.2 to read:
"4. Glazing in walls on the latch side of and perpendicular to the plane of the door in a closed position in buildings of Group R-5 occupancy or within dwelling units and sleeping units in other Group R occupancies."
3. Revise exception 1 to Section 2406.4.6 to read:
"1. The side of a stairway, landing or ramp that has a guard complying with the provisions of Sections 1015 and 1607.8."
4. Revise the exception to Section 2406.4.7 to read:
"Exception: Glazing that is protected by a guard complying with Sections 1015 and 1607.8."