14B-11-1109 Other features and facilities.
The provisions of Section 1109 of IBC are adopted by reference with the following modifications:
1.   Revise the exception to Section 1109.1 to read:
"Exception: Accessible units, Type A units, Type B units and Type C units shall comply with Chapter 10 of ICC A117.1."
2.   Add a new Section 1109.5.3 to read:
"1109.5.3 Bottle fillers.
Where a bottle filler is provided, the bottle filler shall be accessible and located on an accessible route."
3.   Revise item 1 in Section 1109.8 to read:
"1.   An accessible route to a performing area, head tables in banquet rooms and spaces and speaker platforms."
4.   Add a new Section 1109.7.1 to read:
"1109.7.1 Limited use/limited application elevators.
Limited use/limited application elevators shall be allowed for the following applications:
1.   For applications listed in Section 1109.8.
2.   For applications subject to an exception to Section 1104.4.
3.   To provide access to the mezzanine or second story above grade plane of a two-story building or to the basement or mezzanine of a one-story building, other than a shopping mall, shopping center, or the professional office of a health care provider, where each story is not more than 3,000 square feet (279 m2)."
5.   Revise Section 1109.9 to read:
"1109.9 Storage.
Where fixed or built-in storage elements such as cabinets, coat hooks, shelves, medicine cabinets, lockers, closets and drawers are provided in required accessible spaces or for Type A units or Accessible units, at least 5 percent, but not less than one of each type shall be accessible.
Exception: Archival storage areas and product storage areas described in Section 1104.4, exception 4 are not required to be accessible."
6.   Revise Section 1109.9.2 to read:
"1109.9.2 Shelving and display units.
Self-service shelves and display units shall be located on an accessible route. Such shelving and display units shall not be required to comply with reach-range provisions. The clear width of aisles between stacks in libraries shall be 42 inches (1065 mm) minimum.
Exception: In existing buildings and alterations, the minimum width of aisles between stacks in libraries shall be 36 inches (915 mm)."
7.   Add new Sections 1109.12.1.1 and 1109.12.1.2 to read:
"1109.12.1.1 Coat hooks, shelves and mirrors.
Where coat hooks, shelves or mirrors are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall be accessible. Where coat hooks, shelves or mirrors are provided in individual compartments required to be accessible, at least one of each type shall be accessible within the compartment.
1109.12.1.2 Mirrors.
Where mirrors are provided in dressing rooms of the same use, then at least one accessible mirror shall be provided in an accessible dressing room."
8.   Add a new Section 1109.13.1 to read:
"1109.13.1 Operable windows.
Where operable windows are provided for operation by occupants, at least one operable window in each room shall be accessible and each required operable window shall be accessible.
Exceptions:
1.   Windows in bathrooms and kitchens.
2.   In Group R-1 occupancies, only windows in Accessible units are required to be accessible."