You are viewing an archived code
The maximum water consumption flow rates and quantities for all plumbing fixtures and fixture fittings shall be in accordance with Table 18-29-604.4. Water consumption for urinals listed in the following exceptions shall not be greater than 1.5 gallons (5.7 L) per flushing cycle.
Exceptions:
1. Blowout design fixtures.
2. Penalware.
3. Clinical sinks.
4. Service sinks.
5. Emergency showers.
Plumbing Fixture or Fixture Fitting | Maximum Flow Rate or Quantity a |
Plumbing Fixture or Fixture Fitting | Maximum Flow Rate or Quantity a |
Lavatory, private | 2.5 gpm at 80 psi |
Lavatory, public | 0.5 gpm at 80 psi |
Lavatory, public, metering or self-closing | 0.5 gallons per metering cycle |
Shower head | 2.5 gpm at 80 psi |
Sink faucet | 2.5 gpm at 60 psi |
Urinal | 1.0 gallons per flushing cycle |
Water closet | 1.6 gallons per flushing cycle |
For SI: 1 gallon = 3.785 L, 1 gpm = 3.785 L/m, 1 psi = 6.895 kPa
a Consumption tolerances shall be determined from referenced standards