18-29-403.1  Minimum number of fixtures.
   Plumbing fixtures shall be provided for each occupancy and use in the minimum number shown in Table 18-29-403.1. Occupancies and uses not shown in Table 18-29-403.1 shall be considered individually by the building commissioner. Occupancies and the number of persons (for various occupancies and uses) shall be as determined by Chapter 13-56.
Table 18-29-403.1
Minimum Number of Plumbing Facilities a for New Buildings or Buildings With a Change of Occupancy
For a printer-friendly PDF version of Table 18-29-403.1, please click here.
OCCUPANCY/USE
WATER CLOSETS (Urinals, see Section 419.2)
LAVA- TORIES
BATHTUB/ SHOWERS
DRINKING FOUNTAINS (See Section 410.1)
OTHERS
Male
Female
OCCUPANCY/USE
WATER CLOSETS (Urinals, see Section 419.2)
LAVA- TORIES
BATHTUB/ SHOWERS
DRINKING FOUNTAINS (See Section 410.1)
OTHERS
Male
Female
A
S
S
E
M
B
L
Y
Restaurants and Nightclubs (more than 100)
1 per each 30 to 90
1 per each 25 up to 100
1 per 50
1 per 500
1 service sink
1 per each 50 above 90
1 per each 30 above 100
Theaters, halls, museums, coliseums, arenas, etc.
1 per each 30 up to 60
1 per each 15 up to 60
1 per 1,000
1 service sink
1 per each 70 between 61 and 340
1 per each 30 between 61 and 340
1 per each 100 above 340
1 per each 50 above 340
Churches b
1 per each 30 up to 90
1 per each 20 up to 100
1 per 1,000
1 service sink
1 per each 50 above 90
1 per each 25 above 100
Stadiums, etc. (open air)
1 per each 60 up to 240
1 per each 30 up to 240
1 per 50
1 per 1,000
1 service sink
1 per each 100 between 241 and 1040
1 per each 50 between 241 and 1040
1 per each 150 above 1040
1 per each 75 above 1040
Health Club
1 per each 30 up to 90
1 per each 25 up to 100
1 per 50
1 per 500
1 service sink
1 per each 50 above 90
1 per each 30 above 100
Business
(see Sections
403.2, 403.4 and 403.5)
1 for first 10
2 for 11 – 25
1 additional for each 25 in excess of 25
1 per 40
1 per 100
1 service sink
Educational
1 per 100
1 service sink
Factory and industrial
(See Section 411)
1 per 400
1 service sink
High hazard
(see Sections
403.2 and 403.4)
(See Section 411)
1 per 1,000
1 service sink
I
N
S
T
I
T
U
T
I
O
N
A
L
Residential care
1 per 10
1 per 10
1 per 8
1 per 100
1 service sink
Hospitals, ambulatory nursing home patients c
1 per room d
1 per room d
1 per 15
1 per 100
1 service sink per floor
Day nurseries, sanitariums, non-ambulatory nursing home patients, etc. c
1 per 15
1 per 15
1 per 15 e
1 per 100
1 service sink
Employees, other than residential care c
1 per 25
1 per 35
1 per 100
Visitors, other than residential care
1 per 75
1 per 100
1 per 500
Prisons c
1 per cell
1 per cell
1 per 15
1 per 100
1 service sink
Asylums, reformatories, etc. c
1 per 15
1 per 15
1 per 15
1 per 100
1 service sink
M
E
R
C
A
N
T
I
L
E
Mercantile – Stores, malls, etc. (see Sections 403.2, 403.4 and 403.5)
1 per each 25 up to 100
1 per each 15 up to 90
1 per 40
1 per 1,000
1 service sink
1 per each 40 above 100
1 per each 25 above 90
Mercantile – Restaurants & nightclubs of 100 or less
(see Sections
403.2, 403.4 and 403.5)
1 per each 30 to 90
1 per each 25 up to 100
1 per 50
1 per 500
1 service sink
1 per each 50 above 90
1 per each 30 above 100
R
E
S
I
D
E
N
T
I
A
L
Hotels, motels
1 per guestroom
1 per guest- room
1 per guestroom
1 service sink
Lodges
1 per 10
1 per 10
1 per 8
1 per 100
1 service sink
Multiple family
1 per dwelling unit
1 per dwelling unit
1 per dwelling unit
1 kitchen sink per dw. unit., 1 auto. clothes washer connect per 20 dw. units
Dormitories
1 per 10
1 per 10
1 per 8
1 per 100
1 service sink
One- and two-family dwellings
1 per dwelling unit
1 per dwelling unit
1 per dwelling unit
1 kitchen sink per dw. unit.; 1 auto. clothes washer connection per dwelling unit f
Storage
(see Sections
403.2 and 403.4)
1 per 100
1 per 100
(see Section 411)
1 per 1,000
1 service sink
 
a The fixtures shown are based on one fixture being the minimum required for the number of persons indicated or any fraction of the number of persons indicated. The number of occupants shall be determined by the building code.
b Fixtures located in adjacent buildings under the ownership or control of the church shall be made available during periods the church is occupied.
c Toilet facilities for employees shall be separate from facilities for inmates or patients.
d A single-occupant toilet room with one water closet and one lavatory serving not more than two adjacent patient rooms shall be permitted where such room is provided with direct access from each patient room and with provisions for privacy.
e For day nurseries, a maximum of one bathtub shall be required.
f For attached one- and two-family dwellings, one automatic clothes washer connection shall be required per 20 dwelling units.
(Amend Coun. J. 3-27-02, p. 82090, § 3; Amend Coun. J. 11-13-07, p. 14999, Art. II, § 1)