Skip to code content (skip section selection)
Compare to:
Chicago Overview
Prior Chicago Building Code
BUILDING CODE AND RELATED EXCERPTS OF THE MUNICIPAL CODE OF CHICAGO
DIVISION 1 - ADMINISTRATION
DIVISION 2 - DEFINITIONS
DIVISION 3 - USE AND OCCUPANCY CLASSIFICATIONS
DIVISION 4 - SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
DIVISION 5 - GENERAL BUILDING HEIGHTS AND AREAS
DIVISION 6 - TYPES OF CONSTRUCTION
DIVISION 7 - FIRE-RESISTANCE-RATED CONSTRUCTION
DIVISION 8 - INTERIOR FINISHES (NA)
DIVISION 9 - FIRE PROTECTION SYSTEMS
DIVISION 10 - MEANS OF EGRESS
DIVISION 11 - ACCESSIBILITY
DIVISION 12 - INTERIOR ENVIRONMENT
DIVISION 13 - ENERGY EFFICIENCY AND ENVIRONMENTAL PROTECTION
DIVISION 14 - EXTERIOR WALLS (NA)
DIVISION 15 - ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (NA)
DIVISION 16 - STRUCTURAL DESIGN
DIVISION 17 - STRUCTURAL TESTS AND SPECIAL INSPECTIONS
DIVISION 18 - SOILS AND FOUNDATIONS
DIVISION 19 - CONCRETE
DIVISION 20 - ALUMINUM (NA)
DIVISION 21 - MASONRY
DIVISION 22 - STEEL
DIVISION 23 - WOOD
DIVISION 24 - GLASS AND GLAZING (NA)
DIVISION 25 - GYPSUM BOARD AND PLASTER (NA)
DIVISION 26 - PLASTIC (NA)
DIVISION 27 - ELECTRICAL
DIVISION 28 - MECHANICAL SYSTEMS
DIVISION 29 - PLUMBING SYSTEMS
DIVISION 30 - ELEVATORS AND CONVEYING SYSTEMS
DIVISION 31 - SPECIAL CONSTRUCTION (NA)
DIVISION 32 - ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
DIVISION 33 - SAFEGUARDS DURING CONSTRUCTION
DIVISION 34 - EXISTING STRUCTURES
DIVISION 35 - REFERENCED STANDARDS

You are viewing an archived code

DIVISION 19 – CONCRETE
CHAPTER 13-136
CONCRETE CONSTRUCTION
Article I.  Plain and Reinforced Concrete
13-136-010   Standards.
13-136-020   Exceptions.
Article II.  Gypsum Concrete
13-136-030   Standards.
13-136-040   Exceptions, supplement, additions and corrections.
ARTICLE I.  PLAIN AND REINFORCED CONCRETE (13-136-010 et seq.)
13-136-010  Standards.
   Except as provided in Section 13-136-020 of this Code, the design and construction of plain and reinforced concrete shall be in accordance with the following documents: Building Code Requirements For Reinforced Concrete (ACI 318-83), supplemented by the Building Code Requirements for Structural Plain Concrete (ACI 318.1-83).
(Prior code § 73-1; Amend Coun. J. 11-29-89, p. 8413)
13-136-020  Exceptions.
   Exceptions to ACI 318-83 – The provisions of ACI 318-83 shall be subject to the following exceptions for purposes of this Code:
   (a)   The requirements contained in ACI 318-83, Sections 1.1.2, 1.2.3, shall not apply. Instead, the applicable provisions of this Code shall apply.
   (b)   The requirements of Section 1.1.4, ACI 318-83, shall be supplemented as follows:
   Tanks, reservoirs and other hydraulic structures shall be designed by using the alternate design method and complying with the provisions of Sections 8.1.2 of ACI 318-83, or by using the strength design recommendations of ACI Committee 350.
   (c)   The requirements of Section 1.3, ACI 318-83, are modified as follows:
   Items b, e, g and h in Section 1.3.2 shall not apply, instead the following shall be substituted and shall apply:
   Since it is the responsibility of the concrete contractor, who shall be licensed in accordance with the provisions of Chapter 4-376 of the Municipal Code of Chicago, to erect, maintain, and provide for properly designed forms and shores; the concrete contractor shall keep a record which shall cover: form placement and removal; reshoring, sequence of erection and connection of pre-cast members; any significant construction loadings on completed floors, members or walls; and general progress of the work.
   (d)   The requirements of Section 1.4, ACI 318-83, shall not apply. Instead, the provisions of the Municipal Code for materials, methods, or systems of construction shall apply.
   (e)   The requirement of Section 5.4.4, ACI 318-83, “unless approved by the engineer” shall not apply.
   (f)   The requirements of Section 10.2.6, ACI 318-71, are supplemented as follows:
   The relationship between concrete compression strength and strain for all members with fc greater than 8,000 p.s.i. shall be based on the provisions of Paragraph 10.2.7, ACI 318-71.
   The requirements of Section 10.2.7, ACI 318-71, are supplemented as follows:
   For the design of columns with fc greater than 8,000 p.s.i., an investigation shall be made to verify the stress-strain relationship of concrete, or design shall be based on a concrete stress distribution which is defined as follows:
   The concrete stress shall be assumed to vary parabolically with strain from zero to a maximum value of 0.85 fc and then to remain constant until the maximum usable strain is reached. The parabola shall have its vertex at stress of 0.85 fc and its slope at zero stress shall not exceed 1,000 fc or ec, whichever is greater. Any other stress distribution, including that defined in Section 10.2.7, ACI 318-71, may be used for fc greater than 8,000 p.s.i. if the results are consistent with those obtained by the use of a verified stress-strain relationship.
   (g)   The requirements of Section 15.6.1, ACI 318-71, are supplemented as follows:
   By adding the following provision to supplement the first sentence thereof:
or by structural steel column bases with vertical reinforcement welded to the bases, including provision for anchor bolts, if required. Column bases shall conform to the requirements of AISC, 1969, specification Section 1.21 – Column-Bases.
   By adding the following provision to supplement the second sentence thereof:
or by anchor bolts per AISC, 1969, specification Section 1.2 – Anchor Bolts.
   The requirements of Section 15.6.2, ACI 318-71, are supplemented as follows:
   By adding the following sentence:
   The permissible stress above or below the contact area shall be computed in accordance with the provisions of ACI 318-71, Sections 10.3.6 and 7.10.5.
   (h)   The requirements of Sections 17.1.1 and 17.1.2, ACI 318-71, are supplemented as follows:
   Composite structural steel-concrete members used as composite flexural members shall be designed by the alternate design method and shall comply with the provisions of Sections 8.1.2 and 8.10.1, and Chapter 7 “Details of Reinforcement”, ACI 318-71, and other applicable requirements and shall be in accordance with the requirements of the following document: Specifications for the Design Fabrication and Erection of Structural Steel for Buildings (AISC, 1969).
   (i)   The requirements of Appendix A – Special Provisions for Seismic Design, ACI 318-71, shall not apply.
(Prior code § 73-1.1; Amend Coun. J. 11-29-89, p. 8413)