18-11-1108.2.7.2  Receivers.
   The minimum required number of receivers provided shall be in accordance with Table 18-11-1108.2.7.2. Twenty-five percent of receivers, but not less than two, shall be hearing aid compatible.
   Exceptions:
      1.   If a building contains more than one assembly area and the assembly areas required to provide assistive listening systems are under one management, the total number of required receivers may be calculated based on the total number of seats in the assembly areas in the building, provided that all receivers are usable with all systems.
      2.   If all seats in an assembly area are served by an induction loop assistive listening system, the minimum number of receivers required by Table 18-11-1108.2.7.2 to be hearing-aid compatible shall not be required to be provided.
(Amend Coun. J. 7-26-06, p. 81373, § 1)
Table 18-11-1108.2.7.2
Receivers for Assistive Listening Systems
 
Capacity of Seating in Assembly Area
Minimum Number of Required Receivers
Minimum Number of Required Receivers Required to Be Hearing-aid Compatible
50 or less
2
2
51 to 200
2, plus 1 per 25 seats
over 50 seats
1
2
201 to 500
2, plus 1 per 25 seats
over 50 seats
1
1 per 4 receivers 1
501 to 1,000
20, plus 1 per 33 seats
over 500 seats
1
1 per 4 receivers 1
1,001 to 2,000
35, plus 1 per 50 seats
over 1,000 seats
1
1 per 4 receivers 1
2,001 and over
55, plus 1 per 100 seats
over 2,000 seats
1
1 per 4 receivers 1
 
Note 1. Or fraction thereof.