13-96-271  Construction – Carports.
   (a)   The roof and all load-bearing elements of a carport shall be of noncombustible construction.
   (b)   A carport shall not exceed 800 square feet in roof area.
   (c)   A carport shall not exceed 15 feet and one story in height.
   (d)   Carports shall be open on at least two sides.
   (e)   Carport floor construction shall be of concrete or equivalent noncombustible material, except asphalt surfaces shall be permitted at ground level.
   (f)   Outside the fire limits, the roof and load-bearing elements of a carport may be built of unprotected combustible construction provided that the roof area does not exceed 600 square feet and the carport is located not less than three feet from an interior lot line and not less than six feet from another building or structure on the same lot.
(Added Coun. J. 3-29-17, p. 45477, § 3)