13-96-160  Barbed wire.
   The use of barbed wire at a height less than eight feet above the ground shall be prohibited; provided, however, that the use of barbed wire above six feet from the ground when wholly on or over private property shall be permitted.
(Prior code § 61-5.4)
ARTICLE V.  FIRE STATIONS (13-96-170 et seq.)
13-96-170  General requirements.
   Every fire station hereafter erected shall comply with all applicable provisions of this Code and with the special provisions of Sections 13-96-180 to 13-96-200, inclusive.
(Prior code § 61-6)
13-96-180  Definition.
   A “fire station” is defined as a building or part of a building designed or used as a place for the housing of one or more pieces of fire fighting or salvaging equipment, together with sleeping quarters, locker rooms, toilet rooms, heating plant and such other rooms or spaces as required by the firemen or the equipment.
(Prior code § 61-6.1)
13-96-190  Construction.
   (a)   Fire stations shall be of a type of construction not less fire-resistive than Type III-B.
   (b)   Sleeping quarters and rooms and spaces appurtenant thereto shall comply with all requirements for multiple dwellings.
(Prior code § 61-6.2)
13-96-200  Mixed occupancy.
   A fire station may occupy a part of a building used for business, mercantile, storage, industrial or police station occupancy, provided that such fire station shall be separated from every other part of such building by construction providing fire resistance of not less than two hours.
(Prior code § 61-6.3)