Skip to code content (skip section selection)
Compare to:
Chicago Overview
Prior Chicago Building Code
BUILDING CODE AND RELATED EXCERPTS OF THE MUNICIPAL CODE OF CHICAGO
DIVISION 1 - ADMINISTRATION
DIVISION 2 - DEFINITIONS
DIVISION 3 - USE AND OCCUPANCY CLASSIFICATIONS
DIVISION 4 - SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
DIVISION 5 - GENERAL BUILDING HEIGHTS AND AREAS
DIVISION 6 - TYPES OF CONSTRUCTION
DIVISION 7 - FIRE-RESISTANCE-RATED CONSTRUCTION
DIVISION 8 - INTERIOR FINISHES (NA)
DIVISION 9 - FIRE PROTECTION SYSTEMS
DIVISION 10 - MEANS OF EGRESS
DIVISION 11 - ACCESSIBILITY
DIVISION 12 - INTERIOR ENVIRONMENT
DIVISION 13 - ENERGY EFFICIENCY AND ENVIRONMENTAL PROTECTION
DIVISION 14 - EXTERIOR WALLS (NA)
DIVISION 15 - ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (NA)
DIVISION 16 - STRUCTURAL DESIGN
DIVISION 17 - STRUCTURAL TESTS AND SPECIAL INSPECTIONS
DIVISION 18 - SOILS AND FOUNDATIONS
DIVISION 19 - CONCRETE
DIVISION 20 - ALUMINUM (NA)
DIVISION 21 - MASONRY
DIVISION 22 - STEEL
DIVISION 23 - WOOD
DIVISION 24 - GLASS AND GLAZING (NA)
DIVISION 25 - GYPSUM BOARD AND PLASTER (NA)
DIVISION 26 - PLASTIC (NA)
DIVISION 27 - ELECTRICAL
DIVISION 28 - MECHANICAL SYSTEMS
DIVISION 29 - PLUMBING SYSTEMS
DIVISION 30 - ELEVATORS AND CONVEYING SYSTEMS
DIVISION 31 - SPECIAL CONSTRUCTION (NA)
DIVISION 32 - ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
DIVISION 33 - SAFEGUARDS DURING CONSTRUCTION
DIVISION 34 - EXISTING STRUCTURES
DIVISION 35 - REFERENCED STANDARDS

You are viewing an archived code

Loading...
11-16-220  Reinforced concrete sewer pipe.
   All reinforced concrete sewer pipe shall conform to the latest edition of the A.S.T.M.'s “Standard Specifications for Concrete Sewer Pipe” (Serial Designation: C-76-88).
(Added Coun. J. 2-6-02, p. 78883, § 1)
11-16-230  Reinforced concrete culvert pipe.
   All reinforced concrete culvert pipe shall conform to the latest edition of the A.S.T.M.'s “Standard Specifications for Concrete Sewer Pipe” (Serial Designation: C-76-88).
(Added Coun. J. 2-6-02, p. 78883, § 1)
ARTICLE V.  INSPECTIONS (11-16-240 et seq.)
11-16-240  Inspection – Required.
   Prior to the completion of any work on any drain pipe or sewer, and except as otherwise provided in this section, the department shall inspect the work to determine its compliance with the requirements of this Code, with all rules and regulations promulgated thereunder, and with all other applicable laws.
   It shall be unlawful for any person who constructs, repairs, adjusts, seals, cleans, lines, videotapes a main sewer, or installs any drain pipe, sewer or sewer structure to cover or otherwise complete any work on any drain pipe, sewer or sewer structure without first having requested and passed an inspection by the department; provided, however, that no inspection shall be required for rodding a drain pipe or sewer. If an inspection is not requested as required by this section, the department shall order the drain pipe, sewer or sewer structure to be uncovered so that a manual or closed circuit television inspection can be conducted by or in the presence of a department inspector.
   Any person who violates this section shall be fined $200.00 for the first offense and $1,000.00 for the second and any subsequent offense. Any licensed drain layer who violates this section three or more times within any calendar year shall have his license suspended or revoked in accordance with Section 4-28-140 of this Code.
(Added Coun. J. 2-6-02, p. 78883, § 1)
11-16-250  Inspection – Fees.
   The commissioner shall cause inspections to be made as required by this chapter. All fees for such inspections shall be as set forth in this section; provided, however, that single family residences shall not be subject to an inspection fee under this chapter, nor shall any inspection fee be charged for rodding, repairing, cleaning or lining any building drain or building sewer, or for videotaping the public sewer.
   Inspection fees shall be charged as follows:
      Six-inch diameter and smaller, per foot.....$0.85
      Eight-inch diameter, per foot.....$1.00
      Ten-inch diameter, per foot.....$1.15
      12-inch diameter, per foot.....$1.30
      14-inch diameter, per foot.....$1.45
      15-inch diameter, per foot.....$1.60
      16-inch diameter, per foot.....$1.75
      18-inch diameter, per foot.....$1.90
      21-inch diameter, per foot.....$2.05
      24-inch diameter, per foot.....$2.20
      27-inch diameter, per foot.....$2.35
      30-inch diameter, per foot.....$2.50
      36-inch diameter, per foot.....$2.65
      42-inch diameter, per foot.....$2.80
      Manholes, each.....$22.00
      Catch basins, each.....$22.00
      Inlets, each.....$22.00
      Inspections during non-regular working hours, per hour, in addition to the above, determined pursuant to relevant provision(s) of applicable collective bargaining agreement
      Special inspection fee (per plant) required  by the United States Department of  Agriculture.....$150.00
      Paving contracts involving adjustments to sewer appurtenances, per mile of street paved (or fraction thereof).....$250.00
      Additional inspections required due deficiencies in work per mile (or fraction thereof).....$250.00
(Added Coun. J. 2-6-02, p. 78883, § 1; Amend Coun. J. 11-19-03, p. 14216, § 7.7; Amend Coun. J. 7-29-15, p. 3537, § 3)
11-16-260  Inspections – Access required.
   Any day between the hours of 7:00 a.m. and 6:00 p.m., or in case of an emergency, the commissioner and his authorized agents shall have free and unobstructed access to any part of any premises where house drains, house sewers, sewer structures, cesspools or water closets are connected with or drain into any public sewer. Such access shall be limited to the following purposes: (1) inspecting the construction, condition and usage of any house drain, house sewer, sewer structures, cesspool or water closet; and (2) making necessary repairs or alterations to any house drain, house sewer, sewer structures, cesspool or water closet.
(Added Coun. J. 2-6-02, p. 78883, § 1)