Skip to code content (skip section selection)
Compare to:
CHAPTER 6A
R-1T TOWNHOUSE DISTRICT
SECTION:
10-6A-1: Application Of Prevailing Regulations
10-6A-2: Permitted Uses
10-6A-3: Height Regulations
10-6A-4: Townhouse Use Requirements”
10-6A-1: APPLICATION OF PREVAILING REGULATIONS:
In the proposed development of an R-1T Townhouse development, the applicable provisions from the Subdivision Ordinance relating to streets, required/paved alleys, sidewalks, fire hydrant interval spacing, etc., shall be applied as deemed appropriate. (Ord, 115-8-24, 8-6-2024)
10-6A-2: PERMITTED USES:
A building or premises shall be used only for the following purposes:
   One Townhouse per recorded Lot.
   Townhouse condominiums; requires recorded OCRs to perpetually maintain the common elements in such a condominium regime.
   Institutions of religious, educational or philanthropic nature; off-street parking and setbacks shall be pursuant to the R-2 zoning district.
   Signs in accordance to prevailing Sign Code Regulations.
   Accessory uses and/or structures; inclusive of detention ponds which shall be perpetually privately maintained (via the recorded CCRs).
(Ord, 115-8-24, 8-6-2024)
10-6A-3: HEIGHT REGULATIONS:
No building shall exceed two and one-half stories (21Z) stories or thirty-five (35') in height. (Ord, 115-8-24, 8-6-2024)
10-6A-4: TOWNHOUSE USE REQUIREMENTS:
Building setbacks for structures shall be as follows subject to adjustment via recorded plat notes, recorded easements, and/or bona fide and binding orders from the Zoning Board of Adjustments (ZBA).
   A.   1.   Minimum Lot Area for internal lots:   2000 square feet
      2.   Minimum Lot Area for corner lots:      3000 square feet
   B.   One Townhouse per lot platted for Townhouse use.
   C.   1.   Minimum lot width for internal lots:   30'
      2.   Minimum lot width for corner lots”      35'
   D.   Minimum lot length:               80'
   E.   Minimum front yard building setback:      20'
   F.   Minimum rear yard building setback:      5'
   G.   1.   Minimum side yard building setback - Inner lot 5'; however, townhouses separated by approved firewalls may build to the side lot line where other neighboring structures may abut. In no instance shall a portion of a structure’s eaves, etc., encroach over the neighboring property or cross (the air space) of a platted lot.
      2.   Minimum corner side yard building setback:   10'
   H.   Garage Door setback to right-of-way:         18'
   I.   Maximum height of structures:            35'
NOTE: Section 11-3-5 (A) requires paved alleys in townhouse developments (Ord, 115-8-24, 8-6-2024)