§ 51.081 DISCHARGE DETERMINATION.
   (A)   If any waters or wastes are discharged or are proposed to be discharged to the public sewers, which waters contain the substances or possess the characteristics enumerated in § 51.079 of this chapter, and/or which are in violation of the standards for pretreatment provided in 40 C.F.R. part 403, 6-26-1978, and any amendments thereto, and which in the judgement of the Village Board may have a deleterious effect upon the sewage works, processes, equipment or receiving waters, or which otherwise create a hazard to life or constitute a public nuisance, the Village Board may:
      (1)   Reject the wastes;
      (2)   Require pretreatment to an acceptable condition for discharge to the public sewers;
      (3)   Require control over the quantities and rates of discharge; and/or
      (4)   Require payment to cover the added costs of handling and treating the wastes not covered by existing taxes or sewer charges, under the provisions of § 51.087 of this chapter.
   (B)   If the Village Board permits the pretreatment or equalization of waste flows, the design and installation of the plants and equipment shall be subject to the review and approval of the Village Board, and subject to the requirements of all applicable codes, ordinances and laws.
(Prior Code, § 50.031) (Ord. 88-003, passed 1-19-1988)
§ 51.082 INTERCEPTORS REQUIRED WHEN.
   Grease, oil and sand interceptors shall be provided when, in the opinion of the Village Board, they are necessary for the proper handling of liquid wastes containing grease in excessive amounts, or any flammable wastes, sand or other harmful ingredients; except that, such interceptors shall not be required for private living quarters or dwelling units. All interceptors shall be of a type and capacity approved by the Village Board, and shall be located as to be readily and easily accessible for cleaning and inspection.
(Prior Code, § 50.032) (Ord. 88-003, passed 1-19-1988)
§ 51.083 PRETREATMENT MAINTENANCE.
   Where preliminary treatment or flow-equalizing facilities are provided, they shall be maintained continuously in satisfactory and effective operation by the owner at his or her expense.
(Prior Code, § 50.033) (Ord. 88-003, passed 1-19-1988)
§ 51.084 CONTROL MANHOLE REQUIREMENTS.
   Each industry shall be required to install a control manhole and, when required by the Village Board, the owner of any property serviced by a building sewer carrying industrial wastes shall install a suitable control manhole together with such necessary meters and other appurtenances in the building sewer to facilitate observation, sampling and measurement of the wastes. Such manhole, when required, shall be accessibly and safely located, and shall be constructed in accordance with plans approved by the Village Board. The manhole shall be installed by the owner at his or her expense, and shall be maintained by him or her so as to be safe and accessible at all times.
(Prior Code, § 50.034) (Ord. 88-003, passed 1-19-1988)
§ 51.085 LABORATORY ANALYSIS REQUIREMENTS.
   (A)   The owner of any property serviced by a building sewer carrying industrial wastes shall provide laboratory measurements, tests and analyses of waters and wastes to illustrate compliance with this chapter and any special conditions for discharge established by the village or regulatory agencies having jurisdiction over the discharge.
   (B)   (1)   The number, type and frequency of laboratory analyses to be performed by the owner shall be as stipulated by the village; but, no less than once per year, the industry must supply a complete analysis of the constituents of the wastewater discharge to assure that compliance with the federal, state and local standards are being met.
      (2)   The owner shall report the results of measurements and laboratory analyses to the village at such times and in such a manner as prescribed by the village. The owner shall bear the expense of all measurements, analyses and reporting required by the village.
      (3)   At such times as deemed necessary the village reserves the right to take measurements and samples for analysis by an outside laboratory service.
(Prior Code, § 50.035) (Ord. 88-003, passed 1-19-1988)
§ 51.086 LABORATORY ANALYSIS SAMPLING.
   (A)   All measurements, tests and analysis of the characteristics of waters and wastes to which reference is made in this chapter shall be determined in accordance with the latest edition of IEPA Division of Laboratories Manual of Laboratory Methods, and shall be determined at the control manhole provided, or upon suitable samples taken at said control manhole.
   (B)   In the event that no special manhole has been required, the control manhole shall be considered to be the nearest downstream manhole in the public sewer to the point at which the building sewer is connected.
   (C)   Sampling shall be carried out by customarily accepted methods to reflect the effect of constituents upon the sewage works and to determine the existence of hazards to life, limb and property. The particular analysis involved will determine whether a 24-hour composite of all outfalls of a premises is appropriate or whether a grab sample or samples should be taken.
   (D)   Normally, but not always, BOD and suspended solids analysis are obtained from 24-hour composites of all outfalls, whereas pHs are determined from periodic grab samples.
(Prior Code, § 50.036) (Ord. 88-003, passed 1-19-1988)
§ 51.087 SPECIAL AGREEMENT.
   No statement contained in this subchapter shall be construed as preventing any special agreement or arrangement between the village and any industrial concern whereby an industrial waste of unusual strength or character may be accepted by the village for treatment, subject to payment therefore, in accordance with §§ 51.015 through 51.018 of this chapter, by the industrial concern provided such payments are in accordance with federal and state guidelines for user charge system.
(Prior Code, § 50.037) (Ord. 88-003, passed 1-19-1988)