A. For the efficient use of water, a landscape shall be carefully designed and planned for the intended function of the project. A landscape design plan meeting the following design criteria shall be submitted as part of the Landscape Documentation Package.
1. Plant Material.
a. Any plant may be selected for the landscape, providing the Estimated Total Water Use in the landscape area does not exceed the Maximum Applied Water Allowance. Methods to achieve water efficiency shall include one (1) or more of the following:
i. Protection and preservation of native species and natural vegetation;
ii. Selection of water-conserving plant, tree, and turf species, especially local native plants;
iii. Selection of plants based on local climate suitability, disease and pest resistance;
v. Selection of plants from local and regional landscape program plant lists; and
vi. Selection of plants from local Fuel Modification Plan Guidelines.
b. Each hydrozone shall have plant materials with similar water use, with the exception of hydrozones with plants of mixed water use, as specified in Section 15.54.028 (A)(1)(c)(ii).
c. Plants shall be selected and planted appropriately based upon their adaptability to the climatic, geologic, and topographical conditions of the project site. Methods to achieve water efficiency shall include one (1) or more of the following:
i. Use the Sunset Western Climate Zone System which takes into account temperature, humidity, elevation, terrain, latitude, and varying degrees of continental and marine influence on local climate;
ii. Recognize the horticultural attributes of plants (i.e., mature plant size, invasive surface roots) to minimize damage to property or infrastructure [e.g., buildings, sidewalks, power lines]; allow for adequate soil volume for healthy root growth; and
iii. Consider the solar orientation for plant placement to maximize summer shade and winter solar gain.
d. Turf is not allowed on slopes greater than twenty-five percent (25%) where the toe of the slope is adjacent to an impermeable hardscape and where twenty-five percent (25%) means one (1) foot of vertical elevation change for every four (4) feet of horizontal length (rise divided by run x one hundred (100) = slope percent).
e. High water plants, characterized by a plant factor of 0.7 to 1.0, are prohibited in street medians.
f. A landscape design plan for projects in fire-prone areas shall address fire safety and prevention. A defensible space or zone around a building or structure is required per Public Resources Code Section 4291(a) and (b). Avoid fire-prone plant materials and highly flammable mulches. Refer to the local Fuel Modification Plan Guidelines.
g. The use of invasive plant species, such as those listed by the California Invasive Plant Council, is strongly discouraged.
h. The architectural guidelines of a common interest development, which include community apartment projects, condominiums, planned developments, and stock cooperatives, shall not prohibit or include conditions that have the effect of prohibiting the use of low-water use plants as a group.
2. Water Features.
a. Recirculating water systems shall be used for water features.
b. Where available, recycled water shall be used as a source for decorative water features.
c. Surface area of a water feature shall be included in the high water use hydrozone area of the water budget calculation.
d. Pool and spa covers are highly recommended.
3. Soil Preparation, Mulch and Amendments.
a. Prior to the planting of any materials, compacted soils shall be transformed to a friable condition. On engineered slopes, only amended planting holes need meet this requirement.
b. Soil amendments shall be incorporated according to recommendations of the soil report and what is appropriate for the plants selected (see Section 15.54.024).
c. For landscape installations, compost at a rate of a minimum of four (4) cubic yards per one thousand (1,000) square feet of permeable area shall be incorporated to a depth of six (6) inches into the soil. Soils with greater than six percent (6%) organic matter in the top six (6) inches of soil are exempt from adding compost and tilling.
d. A minimum three (3) inch layer of mulch shall be applied on all exposed soil surfaces of planting areas except in turf areas, creeping or rooting groundcovers, or direct seeding applications where mulch is contraindicated. To provide habitat for beneficial insects and other wildlife, up to five percent (5%) of the landscape area may be left without mulch. Designated insect habitat must be included in the landscape design plan as such.
e. Stabilizing mulching products shall be used on slopes that meet current engineering standards.
f. The mulching portion of the seed/mulch slurry in hydro-seeded applications shall meet the mulching requirement.
g. Organic mulch materials made from recycled or post-consumer shall take precedence over inorganic materials or virgin forest products unless the recycled post-consumer organic products are not locally available. Organic mulches are not required where prohibited by local Fuel Modification Plan Guidelines or other applicable ordinances.
B. The landscape design plan, at a minimum, shall:
1. Delineate and label each hydrozone by number, letter, or other method;
2. Identify each hydrozone as low, moderate, high water, or mixed water use. Temporarily irrigated areas of the landscape shall be included in the low water use hydrozone for the water budget calculation;
3. Identify recreational areas;
4. Identify areas permanently and solely dedicated to edible plants;
5. Identify areas irrigated with recycled water;
6. Identify type of mulch and application depth;
7. Identify soil amendments, type, and quantity;
8. Identify type and surface area of water features;
9. Identify hardscapes (pervious and non-pervious);
10. Identify location, installation details, and twenty-four (24) hour retention or infiltration of any applicable stormwater best management practices that encourage on-site retention and infiltration of stormwater. Project applicants shall refer to the City of Pinole or Regional Water Quality Control Board for information on any applicable stormwater technical requirements. Stormwater best management practices are encouraged in the landscape design plan and examples are provided in Section 15.54.046.
a. Infiltration beds, swales, and basins that allow water to collect and soak into the ground;
b. Constructed wetlands and retention ponds that retain water, handle excess flow, and filter pollutants; and
c. Pervious or porous surfaces (e.g., permeable pavers or blocks, pervious or porous concrete, etc.) that minimize runoff.
11. Identify any applicable rain harvesting or catchment technologies as discussed in Section 15.54.046 and their twenty-four (24) hour retention or infiltration capacity;
12. Identify any applicable graywater discharge piping, system components and area(s) of distribution;
13. Contain the following statement: "I have complied with the criteria of the ordinance and applied them for the efficient use of water in the landscape design plan"; and
14. Bear the signature of a licensed landscape architect, licensed landscape contractor, or any other person authorized to design a landscape. (See Sections 5500.1, 5615, 5641, 5641.1, 5641.2, 5641.3, 5641.4, 5641.5, 5641.6, 6701, 7027.5 of the Business and Professions Code, Section 832.27 of Title16 of the California Code of Regulations, and Section 6721 of the Food and Agriculture Code.)
(Ord. 2020-05 § 2(part), 2020; Ord. 2009-11 § 1(part), 2009).