16.17.120   Subchapter 7 Single-family residential building - mandatory features and devices.
   Section 150.0 MANDATORY FEATURES AND DEVICES
      Section 150.0 of Subchapter 7 of the California Energy Code is amended to read:
   Single-family residential buildings shall comply with the applicable requirements of Sections 150(a) through 150.0(v).
   NOTE: The requirements of Sections 150.0 (a) through (v) apply to newly constructed buildings and substantial remodels. Sections 150.2(a) and 150.2(b) specify which requirements of Sections 150.0(a) through 150.0(r) also apply to additions or alterations. The electric readiness requirements of Sections 150.0 (n), (t), (u) and (v) apply to residential remodels or additions when the applicable system is included in the remodel.
      Subsections 150.0 (a) - (s) are adopted without modification.
         (t)   Heat pump space heater ready. Systems using gas or propane furnace to serve individual dwelling units shall include the following:
         1.   A dedicated 240 volt branch circuit wiring shall be installed within three feet from the furnace and accessible to the furnace with no obstructions. The branch circuit conductors shall be rated at 30 amps minimum. The blank cover shall be identified as "240V ready." All electrical components shall be installed in accordance with the California Electrical Code.
         2.   The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a future heat pump space heater installation. The reserved space shall be permanently marked as "For Future 240V use."
         3.   A designated exterior location for a future heat pump compressor unit.
      Subsections 150.0 (u) - (v) are adopted without modification.
(Ord. 5627 § 2 (part), 2024)