§ 150.120 AREA, HEIGHT, LOT WIDTH AND YARD REQUIREMENTS.
   Within the R-4 Low Density Residential District, no land shall be used, and no structure shall be constructed or used, except in conformance with the following requirements:
   (A)   The maximum impervious surface coverage shall be twenty percent (20%).
   (B)   A side yard abutting a street shall not be less than forty (40) feet in width.
   (C)   Area, frontage and yard requirements. The following requirements shall be the minimum permitted in this district:
 
Area
Frontage (ft.)
Height (ft.)
Front Yard Setback (ft.)
Side Yard Setback (ft.)
Rear Yard Setback (ft.)
Single family dwelling lots with public sewer and water:
1 acre
180
30 or 2 ½ stories, whichever is lesser
40
20
40
Single family dwelling lots without public sewer and water:
1 acre
180
30 or 2 ½ stories, whichever is lesser
40
20
40
Two-family dwelling lots:
1 acre
240
30 or 2 ½ stories, whichever is lesser
40
40
40
 
 
Utility/storage structures: see § 150.011
15 or 2 stories, whichever is lesser
40
20
40
Agricultural structures and machinery:
15 or 2 stories, whichever is lesser
100
100
100
Septic tank, drainfield or mound:
40
20
20
 
   (D)   No septic tank or drain field shall be less than twenty (20) feet from a property line.
   (E)   No mound system shall be located in the front yard.
(Ord. 395, passed 7-6-2010) Penalty, see § 150.999