9-10-2: DELETIONS AND CHANGES:
The following deletions and/or changes are hereby made to the International Residential Code.
Section R101.1 Village of Monee
Section R103.5 The Fee Schedule as set forth in the building code of the Village established in Table 1 entitled Schedule of Permit Fees, shall apply to all mechanical work.
Section R105.2 Building. Delete Exception 1, 2, 5, 7, 10
Section R202 Definition of "Dwelling" and "Dwelling Unit": Any Building that contains occupied space is considered a Dwelling.
Table R301.2(1) Insert design criteria: Ground Snow Load: 25psf; Wind Design, Speed: 90mph; Wind Design, Topographic effects: No; Wind Design, Special Wind Region: No; Wind Design, Wind-borne debris zone: No; Seismic Design Category: A; Subject to Damage from Weathering: Severe; Subject to Damage from Frost Line Depth: 42 inches; Subject to Damage from Termite: Negligible; Winter Design Temperature: minus 3 degrees Fahrenheit; Ice Barrier Underlayment Required: Yes; Flood Hazard: 11/6/2000 FIRM; Air Freezing Index: 2000; Mean Annual Temp: 49.3 degrees Fahrenheit.
Section R313.2 Add additional Exceptions not requiring an automatic fire sprinkler system
   A.   Mixed-use developments, or any phase thereof, that includes single family units with a density of less than 10 units per acre
   B.   Single family homes located more than 15 feet from a principal building
   C.   Single family homes with a density of less than (4) units per acre
   D.   Individual single family homes located on a lot of more than 8,000 square feet in area.
Section R314.8 Add: a heat detector shall be installed in all attached garages of single family homes, duplex homes and townhouses. The heat detector shall be interconnected with the interior smoke alarms and shall cause the interior smoke alarms to sound when activated.
Chapter 11: The Village adopted international energy conservation code shall have priority over this chapter.
Chapter 12-23: The Village adopted international Mechanical code shall have priority over these chapters.
Chapter 24: The Village adopted international Fuel Gas code shall have priority over this chapter.
Chapter 25-33: The Village adopted Illinois plumbing code shall have priority over these chapters.
Chapter 34-43: The Village adopted national electrical code shall have priority over these chapters.
Section P2603.5.1 Insert: 42 inches, 42 inches
(Ord. 1849, 5-9-2018)