1173.01 SUBDIVISION IMPROVEMENTS REQUIRED BEFORE FINAL APPROVAL.
   Except as provided in Section 1173.03, before approval will be given upon any final plat for recording, the following improvements must be installed in the subdivision as shown on such plat.
   (a)   Water Mains. Water mains must be installed together with all necessary appurtenances such as hydrants, valves and curb connections at each lot within the subdivision, all meeting the approval of the Engineer and the Engineer of the City of Cleveland, Division of Water.
   (b)   Storm Sewers. Storm sewers and stormwater management facilities, together with all necessary appurtenances and curb connections for each lot in such subdivision, shall be installed in accordance with the design standards adopted therefor and adequate for the drainage of the streets, the lots fronting thereon and the natural drainage intercepted by such street.
   (c)   Sanitary Sewers. Sanitary sewers together with all necessary appurtenances and curb connections for each lot in the subdivision adopted therefor. Where municipal sanitary sewer facilities are not available, the subdivider shall construct and install such sanitary sewers and sewage treatment facilities as are deemed necessary by the Planning Commission and the Engineer. The design, installation, method of construction and materials must be approved by the Engineer and any other authority having jurisdiction. The approval by the Engineer and his decision deeming the sewers and treatment facilities necessary, shall be based upon a determination of the adequacy of the proposed facilities relative to the natural contours and topography of the area, the proposed population density of the subdivision and the effect of the facilities upon abutting and adjacent properties and upon the public health, safety and welfare of the entire municipality.
   (d)   Prohibition Against Combined Sewers. No sewer, whether storm or sanitary, shall be approved or installed which is used or designed to be used for the discharge of both stormwater or roof drains and the discharge of septic tanks or other sanitary effluent. All sewers, excluding house laterals, shall be installed in dedicated streets or in easements granted to the Municipality in legal form satisfactory to the Law Director, shall have proper outlets approved by the Engineer, shall serve all lots and lands in the subdivision, and shall go to the boundaries of the subdivision.
   (e)   Streets. All street compactions, grades, subgrades, curbs, curb drains, pavements and all other aspects of street improvement shall be designed, installed, constructed and improved in accordance with plans and specifications therefor submitted to and approved by the Engineer. All street plans and specifications shall at least meet design standards adopted by Planning Commission, unless a deviation from such standards is granted or permitted pursuant to subsection (j).
   (f)   Sidewalks. Sidewalks of Portland cement concrete or similar material which has been approved by the Engineer and shown as an improvement on the plat shall be constructed on both sides of each street and shall extend to the outermost boundaries of the subdivision, even if such sidewalk does not meet with an existing sidewalk, in order to provide for future coterminous sidewalks throughout the Village. Sidewalks shall be at least five (5) feet in width. Pavement thickness shall be four (4) inches and not less than six (6) inches in thickness across driveways. Sidewalks shall be installed prior to final plat approval unless Planning Commission determines that such sidewalks may be installed at a fixed time subsequent to the final approval of the plat and so long as sufficient security is provided for the installation of such sidewalks pursuant to Village of Glenwillow Subdivision Regulation 1173.03 in the form of an escrow deposit, a letter of credit or a bond.
   (g)   Monuments. Monuments to locate streets lines shall be installed in accordance with Section 1172.08 and as specified in the "Standard Drawings-Pavement and Right of Way Details and Minimum Standards".
   (h)   Trees. Street trees shall be installed in accordance with Section 1172.12 prior to final plat approval unless Planning Commission determines that such trees may be installed at a time subsequent to the final approval of the plat and so long as sufficient security to provide for the installation of such trees is provided pursuant to Village of Glenwillow Subdivision Regulation 1173.03 in the form of an escrow deposit, a letter of credit or a bond.
   (i)   Common Areas. Common area and the site improvements shall be shown on plans and specifications submitted by the subdivider and approved by the Engineer.
   (j)   Deviation From Design Standards. The Planning Commission may permit, as to any of the specific improvements or installations in this section, deviation from the design standards after receiving the recommendation of the Engineer as to the proposed deviation. The Planning Commission in granting such deviation, and the Engineer in making his recommendation, shall base their decision and recommendation on either:
      (1)   The improvement under the proposed deviation from the design standards will be equally effective, safe, adequate and desirable as the improvements would be under such standards, and that the improvements under the proposed deviation will perform the same function as and have a life of usefulness equal to the improvement made pursuant to such standards; or
      (2)   The strict application of the design standards to improvements which are under construction for which have been fully planned and contracted for at the time this section becomes fully effective would cause extreme undue hardship or practical difficulty. However, no deviation under subsection (j)(1) or (2) hereof shall be approved that is not in harmony with the general purpose and intent of these regulations or which will interfere with the public health, safety or general welfare.
         (Ord. 2016-07-24. Passed 8-3-16.)