18-29-1203.2  Dressing room drainage.
   Dressing rooms for every nonprivate swimming pool shall be satisfactorily drained. This requirement shall be deemed to have been satisfied when the following conditions are met:
   1.   The dressing rooms are located adjacent to the locker or check room and showers.
   2.   Floors have a minimum pitch of 3 inches (75 mm) in 10 feet to the drains with no low spots which will allow water to stand.
   3.   Hose bibs of 3/4 inch (20 mm) minimum size and served by not less than a 3/4 inch (20 mm) pipe are provided to enable the entire dressing room to be conveniently flushed by hose.