18-28-1203.11.1  Compression-type fittings.
   If compression-type fittings include inserts and ferrules or O-rings, the fittings shall be installed without omitting the inserts and ferrules or O-rings.
18-28-1203.11.2  Plastic-to-metal connections.
   Soldering on the metal portion of the system shall be performed at least 18 inches (457 mm) from a plasticto-metal adapter in the same water line.
18-28-1203.12  PVC plastic pipe.
   Joints between PVC plastic pipe and fittings shall be solvent-cemented or threaded joints conforming to Section 18-28-1203.3.
18-28-1203.13  Steel pipe.
   Joints between steel pipe or fittings shall be mechanical joints that are made with an approved elastomeric seal, or shall be threaded or welded joints conforming to Section 18-28-1203.3.