You are viewing an archived code
All lumber used for load supporting purposes, including edge-jointed or edge-glued lumber, shall be identified by the grade stamp of an approved lumber grading agency or an approved lumber inspection agency certified by the American Lumber Standards Committee and acceptable to the building commissioner. In lieu of a grade stamp on the material, a certificate of inspection as to material and grade shall be acceptable for precut, remanufactured or rough-sawn lumber and for sizes larger than three inches nominal thickness and such certificate of inspection shall be issued by a lumber grading agency or a lumber inspection agency approved by the American Lumber Standards Committee.
(Added Coun. J. 6-14-95, p. 2832; Amend Coun. J. 3-5-03, p. 104990, § 31; Amend Coun. J. 11-13-07, p. 14999, Art. II, § 1)