Skip to code content (skip section selection)
Compare to:

You are viewing an archived code

18-11-1109.5.2  Drinking fountains – minimum number.
   A minimum of two drinking fountains shall be provided. Fifty percent of the total number provided shall be accessible. Fifty percent shall have a spout height of 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above finish floor.
   Exceptions:
      1.   The requirement for a minimum of two drinking fountains shall not apply if a single drinking fountain is provided that complies with the provisions for an accessible drinking fountain and the provision for a spout height of 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above finish floor.
      2.   When applying the 50 percent requirement to an odd number of drinking fountains, the number may be rounded up or down provided that the total number of drinking fountains that comply with this section equals 100 percent of drinking fountains.