Roll-in showers provided in accessible units shall include a permanently mounted folding shower seat.
(Amend Coun. J. 7-26-06, p. 81373, § 1)
Total Number of Units Provided | Minimum Required Number of Accessible Guestrooms | Minimum Required Number of Accessible Units Associated with Roll-in Showers | Number of Additional Units Required to Have Communication Features (Note 1, 2, 3) |
Total Number of Units Provided | Minimum Required Number of Accessible Guestrooms | Minimum Required Number of Accessible Units Associated with Roll-in Showers | Number of Additional Units Required to Have Communication Features (Note 1, 2, 3) |
1 | 1 | 0 | 1 |
2 to 25 | 5% of total, not less than 1 | 0 | 2 |
26 to 50 | 5% of total | 0 | 4 |
51 to 75 | 5% of total | 1 | 7 |
76 to 100 | 5% of total | 1 | 9 |
101 to 150 | 5% of total | 2 | 12 |
151 to 200 | 5% of total | 2 | 14 |
201 to 300 | 5% of total | 3 | 17 |
301 to 400 | 5% of total | 4 | 20 |
401 to 500 | 5% of total | 4 plus 1 for each additional 100 over 400 | 22 |
501 to 1,000 | 5% of total | 1% of total | 5% of total |
Over 1,000 | 5% of total | 10 plus 1 for each 100 over 1,000 | 50 plus 3 for each 100 over 1,000 |
Note 1. Overlap of the required number of accessible guestrooms with the required number of rooms with communication features shall be in accordance with Section 18-11-1107.5.1.1.2.
Note 2. Visual notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell. Notification devices shall not be connected to visual alarm signal appliances. Permanently installed telephones shall have volume controls and an electrical outlet complying with ICC/ANSI A 117.1 located within 48 inches (1219 mm) of the telephone to facilitate the use of a TTY.
Note 3. Visible alarm notification appliances shall be provided in these rooms and shall be activated by both the in- room smoke alarm and the building fire alarm system.
(Amend Coun. J. 7-26-06, p. 81373, § 1)